Ebyte E180-Z5812 Series User Manual page 39

Tlsr8258 2.4ghz zigbee3.0 multi-function soc wireless module
Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co., Ltd.
Manufacturer code=0x0000
Reply mode=0
Command ID=0x00
Command parameter=[01 00 00 FE 01 00]
Analyze the command parameters according to "Zigbee Cluster Library". The parameters of the security alarm command are as shown
in the table.
Command parameters:
[01 00] [00] [FE] [01 00]
The contents in "[ ]" are as follows
Alarm status = 0x0001. According to the sensor protocol specification, you also need to write the attribute "security alarm
status" to this value.
extended status=0x00
Defense zone ID=0xFE, this value also needs to be written simultaneously with the attribute "defense zone ID"
Alarm delay=0x0001, unit 250ms.
Attachment: Notes on sensor trigger control commands:
Sensors are mostly dormant terminals and have a high failure rate in sending commands. Each time the alarm command is
retransmitted, an "alarm delay" needs to be accumulated based on time.
The "alarm status" and "defense zone ID" in the alarm command need to be synchronized with the attributes "security
alarm status" and "defense zone ID" in the device. It is recommended that when the MCU detects an alarm during operation,
write these two attribute values first, and then Read these two attributes and send the alarm command regularly with a cycle
of 250ms. The timing will not stop until the alarm command is sent successfully.
Receive feedback command after issuing ZCL control command:
55 05 02 0F [00] 75 78
Send command is valid
Receive sending confirmation command:
55 0A 8F 02 [00] [00 00] [01] [75] [01] [00] F8
The contents in "[ ]" are as follows
Send mode = 0x00, port index 0 sends command, no mode.
Target short address=0x0000
Destination port=0x01
Frame number=0x75
Command direction=Server->Client, this is a command sent from the controlled end to the control end, and the sensors are
all controlled ends.
Sending result=0x00, sending successfully
Because the default return frame was not turned off when sending, the default return frame from the coordinator was also
received.
55 10 82 0B [20] [00 00] [01] [75] [00] [00 05] [00 00] [C8] [00] [00] 10
The contents in "[ ]" are as follows
Receive mode = 0x20, the received signal strength is valid, and the local port index 0 is port 0x02 that receives the
Copyright © 2012–2024 , Chengdu Ebyte Electronic Technology Co., Ltd.
E180-Z5812 Series User Manual
35