E180-Z5812 supports ADC. Use the "read local attributes" command to read attributes 0x0100 and 0x0101. These two attributes
are the ADC values of ADC1 and ADC2 respectively. You can also remotely access the ADC through the ZCL command to read
cluster 0xFC08. Attributes 0x0100 and 0x0101 under (need to use manufacturer code 0x2000).

4.2 Universal mode

Universal mode is a new function in HEX command mode. In this mode, the module can be configured according to ZCL
standard specifications and simulate various smart devices that comply with ZCL specifications. The configured module in universal
mode can be correctly identified as the corresponding access device when connected to a third-party smart gateway (such as a Zigbee
gateway), and can send and receive control instructions for the gateway to interact with the device.

4.2.1 Precautions for universal mode

In the universal mode, the node must be configured when not connected to the network in order to simulate the access of various
Zigbee smart devices and the sending and receiving of control instructions.
When using universal mode, you must first use the "Create ZCL Port" command to create a device port, then use "Add
Properties" to add all properties under this port, and then use "Save Port and Properties" to save the properties created for this
port.
When adding attributes, the attribute ID must be added from small to large first, and then the cluster ID must be added from
small to large. After all the attributes under a cluster are filled up, the attributes of the next cluster will be added.
When creating a port, you must fill in the cumulative attributes of all clusters under the port. If the actual added attributes are
greater than this value, the addition will fail.
When adding attributes, the actual attribute clusters added can be more than the clusters planned to be added when creating the
port. These clusters will not be discovered by the gateway after the device is connected to the gateway, but if the gateway is
forced to read the attributes under these clusters, it will be valid. numerical value. (can also be called hidden cluster)
In the coordinator and routing node modes, the cumulative number of added ports does not exceed 8, the cumulative number of
added attributes for 8 ports does not exceed 32 clusters, and the cumulative number of added attributes does not exceed 128
items.
In terminal node and dormant node modes, the cumulative number of added ports does not exceed 6, the cumulative number of
added attributes for 6 ports does not exceed 24 clusters, and the cumulative number of attributes added does not exceed 96 items.
You need to modify the ZCL attribute configuration information, or fall back to the transparent transmission module mode, and
directly use "Clear Ports and Attributes". This command must be exited from the network or not connected to the network to take
effect.
Copyright © 2012–2024 , Chengdu Ebyte Electronic Technology Co., Ltd.
0x02/0x82
0x02
0x02/0x82
0x03
0x02/0x82
0x04
0x02/0x82
0x05
0x82
0x0A
0x82
0x0B
0x02
0x0F
0x82
0x0F
E180-Z5812 Series User Manual
14

Advertisement

Table of Contents
loading

Table of Contents