serial port instructions to create ports and initialize attribute values on the zigbee module, and then the module hardware is
connected to the MCU, and the MCU application only processes the application layer of command interaction and device control,
eliminating the need to design, create ports and initialize properties.

4.2.3 Universal mode usage tutorial

Note:
See Chapter 6 for instructions on how to use universal mode.

4.3 Transparent transmission mode

In data transparent transmission mode, any data input to the serial port will be sent out through wireless signals. The module that
receives the transparent transmission data directly prints the data frame in transparent transmission mode or AT command mode. For
example, the receiving end is in HEX command mode. Then the frame data is output in ZCL command format.

4.3.1 ZCL specification for data transparent transmission

Data transparent transmission complies with ZCL specifications, and the specifications are as follows. Any Zigbee device can
send and receive data input and output from the E180-Z5812 serial port as long as it is set according to the following specifications.
port=1
Profile=0x0104
cluster=0xFC08
manufacture code=0x2000
Command type: Special Command
Command direction: Server to Client
Command ID: 0x00
Note: When the coordinator or other nodes are in HEX mode and send data to the E180ZG120 module in transparent
transmission mode, they also need to follow the ZCL specification, that is, use cluster=0xFC08 cluster, Manufacturing Code=0x2000,
and change the command direction to Client to Server. The command ID is 0x00.

4.3.2 Target setting of data transparent transmission

The data transparent transmission target sets the module's local attribute DstAddr and local attribute DstEP. These two attributes
are located at port 1 of the module, cluster=0xFC08. The attribute IDs are 0x0001 and 0x0002 respectively, and the data types are
UINT16 and UINT8 respectively.
DstAddr is the short address of transparent transmission reception, and DstEP is the target port of transparent transmission
reception. Transparent transmission has four modes: on-demand transmission, broadcast transmission, multicast transmission, and
binding transmission. When DstEP is set to other values, it is used to reserve transparent transmission for ZigBee modules with
multiple serial ports.
On demand (to serial
Copyright © 2012–2024 , Chengdu Ebyte Electronic Technology Co., Ltd.
Transparent
transmission mode
On demand (to main
Short address of the other
serial port)
Short address of the other
DstAddr
party
E180-Z5812 Series User Manual