Chengdu Ebyte Electronic Technology Co., Ltd E104-BT10 User Manual 1、 Overview 1.1 Brief Introduction E104-BT10 is a Bluetooth mesh network module designed and manufactured by Ebyte Electronic Technology Co., Ltd., which conforms to the sig mesh V1.0 standard. The single network can accommodate up to 10922 node devices.
Chengdu Ebyte Electronic Technology Co., Ltd E104-BT10 User Manual 2、 Specification and Parameter 2.1 Limit parameter Performance Main Parameter Note Voltage over 3.6V will cause permanent damage Voltage supply [V] to module Chances of burn is slim when modules are used in...
Chengdu Ebyte Electronic Technology Co., Ltd E104-BT10 User Manual Dimension and Pin Definition Pin item Pin direction Application Ground, connecting to power source reference ground PWM output Corresponds to green indicator of SIGMESH HSL PWM output Corresponds to red indicator of SIGMESH HSL...
Chengdu Ebyte Electronic Technology Co., Ltd E104-BT10 User Manual The best advantage of this module is that it can repeater any data in the network. Any module works as a repeater. When as a repeater, it can receive data at the same time. The coverage of the module data signal is about 50 meters. The following figure is a function diagram of repeater for user’s reference.
Chengdu Ebyte Electronic Technology Co., Ltd E104-BT10 User Manual 4.1.1 Network Key(NetKey) Network keys are used to protect network layer communications. It is a key generated using a random number generator that meets the requirements of the core specification.(see details from Mesh Profile3.86)...
(the data compression package includes the APP related SDK for the customer to develop). A single device supports only one role. In EBYTE solution, our module supports two roles: the provisioning node and the mesh node. The provisioning node is the device responsible for networking. The mesh node is the repeater node that sends and receives data and forwards data.
Chengdu Ebyte Electronic Technology Co., Ltd E104-BT10 User Manual Generic Level Server 1002 Generic Default Transition Time Server 1004 Generic Power OnOff Server 1006 Generic Power OnOff Setup Server 1007 Light Lightness Server 1300 Light Lightness Setup Server 1301 Light HSL Server...
Chengdu Ebyte Electronic Technology Co., Ltd E104-BT10 User Manual Networking process steps and results The formation of the entire network is completely automatic. The user only needs to give the "Add Node to Network" command on the serial port. The networking process takes up to 30 seconds, but usually it takes 10 seconds to 20 seconds to succeed.
Any remaining data will be considered invalid and the module will not respond. The parameter configuration is used for parameter configuration of the current module, the SIG message is a standard mesh control message defined by sig, and the transparent transmission message is defined by Ebyte. Length(1byte HEX)...
Page 15
Chengdu Ebyte Electronic Technology Co., Ltd E104-BT10 User Manual 0xFA Assign netkey failure 0xF9 Bind Appkey overtime 0xF8 Bind Appkey failure 0XF7 Last networking not finished 1. NetKey configuration Key is for network ID assigned by provisioner,format is as follows...
Page 16
Chengdu Ebyte Electronic Technology Co., Ltd E104-BT10 User Manual 4. To read AppKey Operation Parameter code Request 0x03 Read 16 bytes of AppKey data Respond 0x03 Return configured 16 bytes of AppKey data :02 C0 03 Request example :12 40 03 11223344556677889900112233445566 Respond Notes:...
Page 17
Chengdu Ebyte Electronic Technology Co., Ltd E104-BT10 User Manual Request 0x06 Serial number +MAC address of allowed device Respond 0x06 MAC address of allowed device Request:09 C0 06 00 112233445566 Respond:33 40 06 01 112233445566 00…00(00...00 means space for example unbound MAC)...
Page 18
Chengdu Ebyte Electronic Technology Co., Ltd E104-BT10 User Manual Request:02 C0 09 example Respond:0B 40 09 112233445566 0004 03 Notes: 1、Suitable for E104-BT10-G 2、Return MAC of networking device and assigned unicast address and element numbers 11.Baud rate configuration Operation code...
Page 19
Chengdu Ebyte Electronic Technology Co., Ltd E104-BT10 User Manual 06:9600 07:4800 Notes: 1、Suitable for E104-BT10-G and E104-BT10-N 13.Power configuration Operation code Parameter Request 0x12 Power number to be configured(range:0x00~0x0A) Respond 0x12 Return configured power number Command Notes 03 C0 12 xx Xx is baud rate serial number to be configured (0x00~0x0A)...
Page 20
Chengdu Ebyte Electronic Technology Co., Ltd E104-BT10 User Manual 08:-28dBm 09:-30dBm 0A:-37bBm Notes: 1、Suitable for E104-BT10-G and E104-BT10-N 15.To read MAC Operation Parameter code Request 0x11 Respond 0x11 Return current MAC address of device Request:02 C0 11 example Respond:08 40 11 112233445566 Notes:...
1、Suitable for E104-BT10-G and E104-BT10-N 2、return unicast address of E104-BT10-N device in current network 4.3.2 SIG Message E104-BT10 supports SIG generic model and Lighting HSL model control ( refer to Mesh Profile and Mesh Model for details about SIG message).SIG message follows format below:...
07 41 00 0B 00 01 80 4A 4.3.3 Transparent transmission E104-BT10 supports transparent transmission of user data. The maximum length of serial port sub-package is 80 bytes. (Mesh under-transport single-package maximum payload is 8 bytes. Data larger than 8 bytes will be automatically sub-packet and sent.
USB serial drive, see the data compression package), open the serial debugging assistant to select the baud rate 115200bps, 8 data bits, no parity, 1 stop bit, select hexadecimal transmission. The E104-BT10-G terminal edits and sends the “Device Access” command 02 C0 09. When E104-BT10-N enters the network successfully, the indicator light is constant.
Chengdu Ebyte Electronic Technology Co., Ltd E104-BT10 User Manual 5.4Transparent transmission 5.4.1 Broadcast transmission Device 0001 broadcasts “ ” in hex format 11223344AA See 3.3,input target address as FFFF ,all device in the network can receive data Transmitting 08 c2 FFFF 11223344AA...
Chengdu Ebyte Electronic Technology Co., Ltd E104-BT10 User Manual See details from Transmitting 08 c2 0002 11223344AA Receiving 09 0A 42 0001 FFFF 11223344AA 6、FAQ 6.1 Communication range is too short The communication distance will be affected when obstacle exists.
Chengdu Ebyte Electronic Technology Co., Ltd E104-BT10 User Manual Please make sure anti-static measures are taken when installing and using, high frequency devices have electrostatic susceptibility. Please ensure the humidity is within limited range for some parts are sensitive to humidity.
Chengdu Ebyte Electronic Technology Co., Ltd E104-BT10 User Manual 8、Series product Frequency TX power Distance Size Model Package Interface E104-BT10 TLSR8269F512 2.4G 19*13 Revision history Version Date Description Operator 2019-4-12 Initial Version About us Website: www.ebyte.com Sales: info@cdebyte.com Support: support@cdebyte.com Tel: +86-28-61399028 Ext.