Ebyte JN5189 User Manual
Ebyte JN5189 User Manual

Ebyte JN5189 User Manual

2.4ghz zigbee multifunction soc wireless module
Table of Contents

Advertisement

Quick Links

Chengdu Ebyte Electronic Technology Co., Ltd.
E78-900M22S User manual
Product specification
JN5189 2.4GHz ZigBee Multifunction SoC Wireless Module
Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
1

Advertisement

Table of Contents
loading

Summary of Contents for Ebyte JN5189

  • Page 1 Chengdu Ebyte Electronic Technology Co., Ltd. E78-900M22S User manual Product specification JN5189 2.4GHz ZigBee Multifunction SoC Wireless Module Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 2: Table Of Contents

    6.5.5 N PAN_ID ..............................26 ETWORK : ............................. 26 6.5.6 N ETWORK SHORT ADDRESS ................................. 27 6.5.7 MAC ADDRESS ....................... 27 6.5.8 P ARENT NODE NETWORK SHORT ADDRESS ..........................27 6.5.9 P ARENT NODE ADDRESS Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 3 LONG ADDRESS IN THE NETWORK 7. FAQ........................................37 ............................37 7.1 P OOR TRANSMISSION RANGE ............................. 37 7.2 M ODULE IS EASY TO DAMAGE ............................. 37 7.3 T HE ERROR RATE IS TOO HIGH ABOUT US........................................ 38 Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 4: Disclaimer

    E180-Z8910SP User Manual Disclaimer EBYTE reserves all rights to this document and the information contained herein. Products, names, logos and designs described herein may in whole or in part be subject to intellectual property rights. Reproduction, use, modification or disclosure to third parties of this document or any part thereof without the express permission of EBYTE is strictly prohibited.
  • Page 5: Product Overview

    The coordinator/router can directly connect to 150 terminal sub-nodes. JN5189 is a wireless microcontroller with great potential to become the first choice for future smart furniture, IoT transformation, and industrial automation. Its network characteristics comply with the ZIGBEE 3.0 standard and provide a complete application integration solution based on the IEEE802.15.4 standard ISM frequency band.
  • Page 6: Introduction Of Equipment Type

    Sleep terminal wake-up can also be awakened through the function pin WAKE. WAKE defaults to high level. Pull down the WAKE pin to wake up the module continuously, and release the WAKE pin to restore the default high-level module Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 7: Application Scenarios

    Chances of burn is slim when modules are used in Blocking power [dBm] short distance Operating temperature [℃] Industrial grade 2.2 Operating parameter Performance Main parameter Note Voltage supply [V] ≥3.3 V ensures output power Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 8 2405 2480 ISM band Transmitting 34.1 Emission current 34.1mA at 11dbm current(mA) Power Receiving current(mA) consumption Turn-off current 1120 Periodic sleep current averages 1120nA (1.1uA) (μA) maximum emitting power [dBm] Air data rate(bps) 250k Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 9 Chengdu Ebyte Electronic Technology Co., Ltd. E78-900M22S User manual Main parameter Description Note Between two points (Zigbee network supports routing multi-hop Distance 500m function, which can extend the transmission distance by adding routers). Support agreement Zigbee 3.0 Single transmission maximum length...
  • Page 10: Dimension And Pin Definition

    Serial transmission port TX PIO9(RX) Input Serial receiving port RX Reserved, directly suspended Reserved, directly suspended PIO2(MOD Input Working mode switching pin, when the pull-down time is greater than 500ms, working mode switching 。 Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 11 The LINK pin indicates the current network status of the module, and the output high-level meter has been added to the network PIO20(PW Output PWM output port 0 Reserved, directly suspended Reserved, directly suspended Reserved, directly suspended Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 12: Operating Mode

    "7A 7D 7E" character; switch to transmission mode via pin, serial port will return to "7F 7C 7B". The details are shown in the figure below: Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 13: Sending And Receiving Method

    ACK to the sending device after receiving the data to indicate that it has received the data. Data (the dormant terminal node has no ACK function). Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 14: Output Mode Of Received Data

    + the short address of the sending device + the RSSI value of the received data packet; 5.2.6 Data + Long Address + RSSI This product does not support this output mode. Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 15: Application Function And Command Configuration

    115200 and 8N1 by pulling this pin down for more than 1000ms. Function pin Pin port LINK PIO21 WAKE PIO1 PIO16 PIO6 UART_BAUD_RESET PIO3 Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 16: Wireless Remote Configuration Function

    (re-entry to the network to change) Destination Read/Write 64bitMAC In fixed-point mode, use long address to send address C、R、E、S Equipment Read/Write They are: coordinator, router, non-sleeping terminal, Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 17 The scanning period is equal to the reconnection period; IO status Read/Write High/low Access/control module GPIO channel level status; 1us~1700ms Read/Write The duty cycle and period of the PWM channel of the Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 18: Hex Instruction Set

    The configuration format is A8 8A FD LEN CMD DATA FF Parameter reading format A8 8A FE LEN CMD (CHANNEL) FF Network operation format: F5 LEN CMD DATA FF F5: fixed head LEN: the actual length of DATA CMD: Actual named ID Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 19: Read Instruction Set

    FE 01 0A FF channel Return: FB 0A channel Return: FB 0A 0B Read transmit power Send: FE 01 0B FF Send: FE 01 0B FF Return: FB 0B txpower Return: FB 0B 0A Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 20 Send: FE 03 20 00 FF GPIO level Return: FB 20 GpioId In/Out Return: FB 20 00 01 01 level Read remote/local Command: FE 06 21 PWMId FF Send: FE 06 21 00 FF Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 21 FE 10 38 FF connection key Send: FE 10 38 FF Return: FB 38 Return: FB 10 TrustCentLinkKey 5A 69 67 42 65 65 41 6C 6C 69 61 6E 63 65 30 39 Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 22: Configuration Instruction Set

    Chengdu Ebyte Electronic Technology Co., Ltd. E78-900M22S User manual 6.4.3 Configuration instruction set Send: FD 01 01 dev_type FF Send: FD 01 01 03 FF Configure device type Return: FA 01 Return: FA 01 Send: FD 02 03 FE 5B...
  • Page 23: Network Operation Instruction Set

    5A 69 67 42 65 65 41 6C Configure the trust Send: FD 10 38 TrustCentLinkKey FF 6C 69 61 6E 63 65 30 39 center connection key Return: FA 38 Return: FA 38 6.4.4 Network operation instruction set Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 24: Hex Parameter Description

    Chengdu Ebyte Electronic Technology Co., Ltd. E78-900M22S User manual Send: F5 01 40 01 FF Send: F5 01 40 01 FF Open network Return: FC 40 00 Return: FC 40 00 Send: F5 01 40 02 FF Send: F5 01 40 02 FF...
  • Page 25: Receive Data Output Mode

    The dormant terminal supports the wake-up function of the serial port receiving pin. The first frame of data sent by the serial port during sleep is the wake-up frame. It is recommended to use the 5-byte "FF" to wake up "FF FF FF FF FF". Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 26: Network Status

    Note: If the coordinator is configured as 0xFFFF, then PANID is randomly selected to establish a network. Terminals, routing, etc. can be configured with 0xFFFF to join any PANID network. PANID parameters need to be configured before joining the network. 6.5.6 Network short address: Read command format: Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 27: Mac Address

    6.5.10 Network group number Read command format: Command format Command example Send: FE 01 09 FF Send: FE 01 09 FF Return: FB 09 group Return: FB 09 01 Configuration instruction format: Command format Command example Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 28: Network Channel

    Send: FD 01 0B 0C FF Return: FA 0B Return: FA 0B txpower: transmit power level, the default is 0C (11dbm), need to be configured before entering the network txpower Transmit power Transmit power level txpower level (dbm) (dbm) Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 29: Serial Port Baud Rate

    Return: FA 0D Return: FA 0D When the node is a dormant terminal, the functions are as follows: sleep_time: (1~60) The sleep wake-up period means 1~60 units (seconds) (61~255) Sleep wake-up cycle representation 60+(sleep_time-60)*10 unit (seconds) Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 30: Parent Node Save Time

    6.5.17 Maximum number of attempts to reconnect Read command format: Command format Command example Send: FE 01 30 FF Send: FE 01 30 FF Return: FB 30 net_rejoincount Return: FB 30 05 Configuration instruction format: Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 31: Wireless Remote Configuration Id

    Send: FD 03 20 00 01 01 FF Return: FA 20 Return: FA 20 The format of gpio peripheral configuration data (3 Byte): GpioId In/Out level. gpioid: channel ID Channel ID GPIO port PIO7 port Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 32: User Pwm Parameters

    Period1 represents the upper 8 bits of the period Period2 means that the lower 8 of the period is duty: pwm duty cycle time (according to the start/stop byte to determine the cycle unit and the maximum cycle) Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 33: User Adc Parameters

    57 B4 14; System sending mode 02; Data output mode 00; Network open time FF (not supported by this module of non-coordinator); Period of rejoin 05; Number of rejoins 05; Wireless ID A8 8A; 6.5.23 Read all network parameters Read command format: Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 34: When Configuring Aux To Wake Up The External Mcu Serial Port In The Wireless Receiving State

    AUX pin to wake up the external MCU, and then delays 4ms to output the serial port data to the external MCU. 6.5.25 Configure the serial port wake-up hold time Read command format: Command format Command example Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 35: Configure Endpoint Information

    0x69 0x67 0x42 0x65 0x65 0x41 0x6C 0x6C 0x69 0x61 0x6E 0x63 0x65 0x30 0x39 Note: This product uses the default trust center connection key of the ZigBee Alliance, and currently does not support configuration changes. Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 36: Firmware Version Command Parameter Description

    Return: FB 15 1F 1C 21 FE FF 57 B4 14 F6 When the short network address of the remote target node is known, this command can be used to read the long network MAC address of the remote target node. Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 37: Faq

    Unsatisfactory power supply may also cause garbled codes. Be sure to ensure the reliability of the power supply;  Poor or too long extension cables and feeders can also cause high bit error rates.  Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 38: About Us

    E180-Z8910SP User Manual About us Technical support: support@cdebyte.com Documents and RF Setting download link: www.ebyte.com Thank you for using Ebyte products! Please contact us with any questions or suggestions: info@cdebyte.com ------------------------------------------------------------------------------------------------- Phone: +86 028-61399028 Web: www.ebyte.com Address: B5 Mould Park, 199# Xiqu Ave, High-tech District, Sichuan, China...

This manual is also suitable for:

E180-z8910sp

Table of Contents