Ebyte E180-Z5812 Series User Manual
Ebyte E180-Z5812 Series User Manual

Ebyte E180-Z5812 Series User Manual

Tlsr8258 2.4ghz zigbee3.0 multi-function soc wireless module
Table of Contents

Advertisement

Quick Links

Chengdu Ebyte Electronic Technology Co., Ltd.
E180-Z5812 Series User Manual
E180-Z5812 Series User Manual
TLSR8258 2.4GHz ZigBee3.0 multi-function SoC wireless module
Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.

Advertisement

Table of Contents
loading

Summary of Contents for Ebyte E180-Z5812 Series

  • Page 1 Chengdu Ebyte Electronic Technology Co., Ltd. E180-Z5812 Series User Manual E180-Z5812 Series User Manual TLSR8258 2.4GHz ZigBee3.0 multi-function SoC wireless module Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
  • Page 2: Table Of Contents

    Contents Disclaimer ..................................6 1 Overview ..................................1 1.1 Product introduction ................................1 1.2 Functional features ................................. 1 1.3 Introduction to equipment types ............................2 1.3.1 Coordinator ....................................2 1.3.2 Router ......................................3 1.3.3 Non-sleeping terminal ................................ 3 1.3.4 Sleep terminal ..................................3 1.4 Application scenarios................................3 2 Specifications ................................4 2.1 Limit parameters ..................................
  • Page 3 5.2.1 Broadcast mode ..................................22 5.2.2 On-demand mode ................................22 5.2.3 Multicast mode ...................................22 5.2.3 Binding transfer mode ..............................22 5.3 Set up binding..................................22 5.3.1 Coordinator remote configuration ..........................22 5.3.2 Set binding with one click ...............................23 5.3.3 View bindings ..................................23 6 Universal Mode Usage Tutorial ..........................25 6.1 Routine 1: Simulate a three-way switch to access the gateway and use APP to control the switch ....25 6.1.1 Create the first switch port and add properties ......................25 6.1.2 Create other switch ports and add properties ......................28...
  • Page 4: Disclaimer

    Disclaimer EBYTE reserves all rights to this document and the information contained herein. Products, names, logos and designs described herein may in whole or in part be subject to intellectual property rights. Reproduction, use, modification or disclosure to third parties of this document or any part thereof without the express permission of EBYTE is strictly prohibited.
  • Page 5: Overview

    1 Overview 1.1 Product introduction The E180-Z5812 series is a ZIGBEE module designed and produced by Chengdu Ebyte based on TELINK TLSR8258 wireless SOC with small size, low power consumption, high reliability, working in the 2.4GHz frequency band. The chip comes with a 32-bit high-performance MCU up to 48Mhz , the transmit power can reach up to 12dBm, and its minimum cycle sleep current is 2uA.
  • Page 6: Introduction To Equipment Types

    The dedicated terminal node supports two device types: End-Device (non-sleep terminal) and Sleep-End-Device (sleep terminal). Note: The E180-Z5812 series only supports routers and terminals. E180-Z5812 SP and E180-Z5812 SX are terminal modules, and E180-Z5812 SP-R and E180-Z5812 SX-R are router modules.
  • Page 7: Router

    Wireless game remote;  Healthcare products;  Wireless voice, wireless headphones;  Advanced Meter Infrastructure (AMI);  Automotive industry applications;  Building automation solutions;  Agricultural greenhouse automation applications;  Copyright © 2012–2024 , Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 8: Specifications

    200m /500m multi-hop function, and the transmission distance can be extended by adding routers). Weight 0.9g Protocol ZigBee 3.0 Package Interface mode 1.27mm Stamp hole IC full name TLSR8258F512ET32 FLASH 512KB Copyright © 2012–2024 , Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 9: Performance Parameters

    96 items (terminal) spaces created Maximum ZCL attribute cumulative 1024 Byte (router) The cumulative size of data data space 768 Byte ( Terminal ) pointed to by all attributes under all ports Copyright © 2012–2024 , Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 10: Mechanical Dimensions And Pin Definitions

    When the pin is pulled low externally, the dormant terminal device will be awakened. PD7(TX) output Serial port transmit port TX PA0(RX) enter Serial receiving port RX Reserved, left empty Copyright © 2012–2024 , Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 11 Reserved, left empty PD2(PWM3) output PWM output port 3 Reserved, left empty Reserved, left empty Reserved, left empty input Output Ground wire, connected to the power reference ground nRESET enter reset pin Copyright © 2012–2024 , Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 12 115200. P B1(ACK) output The ACK pin is used to indicate the last user data transmission status. The pin is pulled low before starting the transmission. After the transmission is Copyright © 2012–2024 , Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 13 P D2 (PWM1) output PWM output port 1 Reserved, left empty Reserved, left empty Reserved, left empty input Output Ground wire, connected to the power reference ground n RESET enter reset pin Copyright © 2012–2024 , Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 14: Serial Port Input And Output

    When the module status changes or data is received, the corresponding HEX command is output in real time through the UART_TX port. For details on the format and analysis of HEX, please refer to the document "Ebyte ZigBee3.0 Module HEX Command Standard Specification". This document focuses on the characteristics of E180-ZG120 in HEX command mode.
  • Page 15 ZCL receive command received. Sending acknowledgment can be used to end waiting for return messages early, and can be used to diagnose other modules or devices for exceptions, instead of wasting limited network resources on meaningless device nodes. Copyright © 2012–2024 , Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 16: Hex Commands Supported By This Product

    4.1.3 HEX commands supported by this product EBYTE's full range of Zigbee products use unified HEX commands. However, due to differences in chip solutions and software configurations, the actual HEX commands supported are different. This section shows the HEX command directory supported by this product.
  • Page 17 Unbind/return node constant connection 0x01/0x81 0x22 View node constant connection 0x01/0x81 0x33 binding/return Delete node/return 0x01/0x81 0x34 ZCL command and ZCL return Read device properties/return 0x02/0x82 0x00 Modify device properties/return 0x02/0x82 0x01 Copyright © 2012–2024 , Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 18: Universal Mode

    You need to modify the ZCL attribute configuration information, or fall back to the transparent transmission module mode, and  directly use "Clear Ports and Attributes". This command must be exited from the network or not connected to the network to take effect. Copyright © 2012–2024 , Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 19: Universal Mode Schematic Block Diagram

    MCU. processing pressure. The initialization information of port creation and attribute values is stored in the FLASH of E180-Z5812, so you can use PC  Copyright © 2012–2024 , Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 20: Universal Mode Usage Tutorial

    When DstEP is set to other values, it is used to reserve transparent transmission for ZigBee modules with multiple serial ports. Transparent DstAddr oeLh transmission mode On demand (to main Short address of the other serial port) party On demand (to serial Short address of the other Copyright © 2012–2024 , Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 21: Binding Transparent Transmission Target

    "AT+command code", and the command code is a fixed string. For detailed analysis of AT commands, please refer to "Ebyte ZigBee 3.0 Module AT Command Standard Specification". There are three input forms of AT commands: execution type, query type, and setting type.
  • Page 22: Query Formula

    AT+ADC Enter test mode AT+TEST Note: The red fonts in the above table are special support instructions for E180-Z5812 series modules . 4. 4.5 New AT command Set or read Modbus ID Copyright © 2012–2024 , Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 23: Mode Switching

    2.1.16")" "Save port -------------------------- -------------------------- attributes" (see "HEX Set attribute 0x0003 to a Set attribute 0x0003 to a Commands" 2.1.28 to non-zero value non-zero value 2.1.30) "AT+EXIT" "AT+SEND" command Copyright © 2012–2024 , Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 24: Precautions For Mode Switching

    HEX mode. In universal mode, only HEX commands can be used for control. In universal mode, HEX commands can also be used to  simulate data transparent transmission. Copyright © 2012–2024 , Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 25: Module Network Distribution And Data Transmission

    5.2 Data transmission Whether the data transmission module is in HEX command mode or data transparent transmission mode, the data transmission Copyright © 2012–2024 , Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 26: Broadcast Mode

    The binding transmission mode is a polling-on-demand method that achieves addressing by locking the MAC address of the target device without needing to remember the other party's short address. E180-Z5812 series modules only use bonded transmission in two situations. A node can bind multiple different target addresses at the same time.
  • Page 27: Set Binding With One Click

    Note: Each node has several virtual devices that can be used as binding objects. Using the Ebyte PC tool, you can easily set the binding source and binding target. When configuring binding remotely, in addition to operating on the coordinator, you can also operate on the router or end node. In addition, if the binding target SN is all 0, it means that the binding target is yourself.
  • Page 28 Chengdu Ebyte Electronic Technology Co., Ltd. E180-Z5812 Series User Manual Note: All bindings can be viewed by clicking "View Constant Connections" in the host computer software. Copyright © 2012–2024 , Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 29: Universal Mode Usage Tutorial

    In universal mode, you need to prepare a zigbee smart gateway (you can choose a crow, a Stanley, a micro, etc.), and use the APP supporting the gateway to add the E180-Z5812 series module. 6.1 Routine 1: Simulate a three-way switch to access the gateway and use APP to control the switch 6.1.1 Create the first switch port and add properties...
  • Page 30 Data type = 0x20 (Data type 0x20 = uint8)  Operation mode = 0x01, supports read-only  Attribute direction = 0x00, this attribute is the server direction (controlled end direction)  Copyright © 2012–2024 , Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 31 The fifth attribute "[04 00] [42] [01]", attribute ID=0x0004, data type=0x42, operation mode=0x01  After adding all the attributes according to the table, save the attributes. input the command: 55 03 00 42 42 Return command: Copyright © 2012–2024 , Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 32: Create Other Switch Ports And Add Properties

    Receiving an asynchronous command indicates a successful reset: 55 0D 80 00 00 [10] [E5 C7 F9 3E 7D 38 C1 A4] 55 The contents in "[]" are as follows Copyright © 2012–2024 , Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 33: Initialize Attribute Values

     Attribute ID=0x0004, the ID of the attribute being written is 0x0004  The written attribute data is 16 bytes, which is the hexadecimal format of the string "EBYTE ZigBee 3.0"  Return command: 55 04 00 43 00 43 Write successfully ...
  • Page 34: Use App To Control Simulated 3-Way Switch

    At the same time, on the APP interface, an interface for searching for new devices appears, which is a three-way switch. 6.1.5 Use APP to control simulated 3-way switch Enter the 3-way switch interface of the APP and trigger switch 2. Copyright © 2012–2024 , Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 35 Port index = 0x01, the property being written is on the second port created (index 1)  Attribute direction = 0x00, the attribute being written is the server side  Copyright © 2012–2024 , Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 36: Example 2: Simulating Human Body Infrared Sensor Access Gateway

    55 11 00 40 [11] [01] [04 01] [02 04] [03] {[00 00] [03 00] [00 05]} [00] 56 The contents in "[ ]" are as follows The switch has a total of 0x11=17 attributes.  Copyright © 2012–2024 , Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 37: Set Attribute Initialization Values And Access The Gateway

    0xF0 (EUI 64) 0x03 (readable and Sever MAC address writable) Zone ID 0x0500 0x0000 0x0011 0x20 (uint8) 0x01 (read only) Sever 6.2.2 Set attribute initialization values and access the gateway Copyright © 2012–2024 , Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 38: Sensor Triggers Alarm

     Frame number=0x75  Command direction=Server->Client, this is a command sent from the controlled end to the control end, and the sensors are  all controlled ends. Cluster ID=0x0500  Copyright © 2012–2024 , Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 39 The contents in "[ ]" are as follows Receive mode = 0x20, the received signal strength is valid, and the local port index 0 is port 0x02 that receives the  Copyright © 2012–2024 , Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 40: Faq

    After the command is issued, the sensor alarm is displayed on the APP. 7 FAQ 7.1 Transmission distance is not ideal When there are straight-line communication obstacles, the communication distance will be correspondingly attenuated;  Copyright © 2012–2024 , Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 41: Modules Are Easily Damaged

    Poor quality or too long extension cords and feeders can also cause a high bit error rate.  Revise history Version Revision date Revision Notes Maintenance man 2024-01-04 initial version Copyright © 2012–2024 , Chengdu Ebyte Electronic Technology Co., Ltd.
  • Page 42: About Us

    Technical support: support@cdebyte.com Documents and RF Setting download link: https://www.ru-ebyte.com Thank you for using Ebyte products! Please contact us with any questions or suggestions: info@cdebyte.com ------------------------------------------------------------------------------------------------- Address: B5 Mould Park, 199# Xiqu Ave, High-tech District, Sichuan, China Copyright © 2012–2024 , Chengdu Ebyte Electronic Technology Co., Ltd.

Table of Contents