TLSR8258 2.4GHz ZigBee multifunctional SOC wireless module
0

Advertisement

Table of Contents
loading

Summary of Contents for Ebyte E180-Z5812SP

  • Page 1 E180-Z5812SP User Manual TLSR8258 2.4GHz ZigBee multifunctional SOC wireless module...
  • Page 2: Table Of Contents

    Chengdu Ebyte Electronic Technology Co., Ltd. E180-Z5812SP User Manual Contents 1. Overview..................................3 1.1 Introduction................................3 1.2 Feature..................................3 1.3 Device type introduction............................4 1.3.1 Non-sleeping terminal............................4 1.3.2 Sleeping terminal..............................4 1.4 Application................................4 2. Parameters................................... 5 2.1 Limit parameter.................................5 2.2 Working parameter..............................5 3.
  • Page 3 Chengdu Ebyte Electronic Technology Co., Ltd. E180-Z5812SP User Manual 6.4.1 Command description............................13 6.4.2 Read command set............................... 14 6.4.3 Configuration command set..........................16 6.4.4 Network operation command set......................... 17 6.5 HEX parameter description............................ 18 6.5.1 System transmission mode...........................18 6.5.2 Receiving data output mode..........................18 6.5.3 Network node type...............................19...
  • Page 4: Overview

    1.1 Introduction E180-Z5812SP is a ZigBee module based on TELINK TLSR8258 wireless SoC designed and produced by Ebyte, which is small size, low power consumption, high reliability and works in 2.4GHz frequency band. The chip has a 32-bit high-performance MCU up to 48mhz, with a maximum transmission power of 12dBm and a minimum sleep current of 2uA.
  • Page 5: Device Type Introduction

    Chengdu Ebyte Electronic Technology Co., Ltd. E180-Z5812SP User Manual One key to restore the baud rate: if the user forgets or does not know the baud rate, this function can be used to  restore the default baud rate to 115200 Serial port receive wakeup: support the serial port receive wakeup function, when the module receives a frame ...
  • Page 6: Parameters

    Chengdu Ebyte Electronic Technology Co., Ltd. E180-Z5812SP User Manual Wireless game remote control  Healthcare products  Wireless voice, wireless headset  Advanced Metering Infrastructure (AMI)  Application in automobile industry  Building automation solutions  Application of agricultural greenhouse automation ...
  • Page 7: Dimension And Pin Definition

    Chengdu Ebyte Electronic Technology Co., Ltd. E180-Z5812SP User Manual 64KB Core chip 32 bit MCU Size 11.5*22mm Antenne 50Ω 3. Dimension and pin definition Direction Description Reserved, suspended Ground Reserved, suspended PD3(WAKE) Input The wake pin is mainly used to wake up the sleepingterminal. The default value is high level.
  • Page 8 Chengdu Ebyte Electronic Technology Co., Ltd. E180-Z5812SP User Manual Reserved, suspended Reserved, suspended PD4(MODE) Input Working mode switch pin, when pull down time is more than 500ms, switch working mode PA1(BAUD_ Input UART_ BAUD_ The reset pin is used to reset the baud rate of the device.
  • Page 9: Working Mode

    Chengdu Ebyte Electronic Technology Co., Ltd. E180-Z5812SP User Manual 4. Working mode 4.1 Transmission mode When the module enters the transmission mode, any data received by the serial port will be sent out wirelessly. The transmission mode is wireless communication between nodes. The communication modes include unicast, protocol unicast, multicast, protocol multicast, broadcast, etc.
  • Page 10: Multicast Mode

    Chengdu Ebyte Electronic Technology Co., Ltd. E180-Z5812SP User Manual 5.1.2 Multicast mode In multicast mode, first set the group number of the devices in the network in the configuration mode (set group, restart valid), the transmitter specifies the target group number in the configuration mode (send the data to specified group), and then the transmitter enters the transmission mode to send the data received by the serial port to the network, and the devices with the same group number in the network will receive the data.
  • Page 11: Data+Rssi

    Chengdu Ebyte Electronic Technology Co., Ltd. E180-Z5812SP User Manual module E180-ZG120A/E180-ZG120B. 5.2.4 Data+RSSI When the output mode is data+RSSI, after the module receives the wireless data, the serial port will output the original data+RSSI value of the received data packet.
  • Page 12: Ack Description

    Chengdu Ebyte Electronic Technology Co., Ltd. E180-Z5812SP User Manual 6.1.4 ACK description ACK pin is used to indicate the status of the data transmission. The pin is low level before the transmission is started, and high level after the transmission is successful. The user can judge whether the data is delivered successfully by the pin status.
  • Page 13 Chengdu Ebyte Electronic Technology Co., Ltd. E180-Z5812SP User Manual Network Read 0、2、3 It indicates the network status of the device, including status no network, successfully joined the network, with network but no parent node. Target Read/Write 0x0000~0xFFFF The communication target address (short address) can...
  • Page 14: Hex Command

    Chengdu Ebyte Electronic Technology Co., Ltd. E180-Z5812SP User Manual n cycle Maximum Read/Write 1~254 times After the maximum number of reconnections is number of exceeded, if the reconnection is not successful, the reconnectio previous network information will be cleared and the new network will be scanned again.
  • Page 15: Read Command Set

    Chengdu Ebyte Electronic Technology Co., Ltd. E180-Z5812SP User Manual LEN: DATA length CMD: Command ID DATA: Parameter FF: Command terminator Configuration return: FC CMD STATUS FC: Fixed head CMD: Command ID STATUS: 00 success 01 fail 6.4.2 Read command set...
  • Page 16 Chengdu Ebyte Electronic Technology Co., Ltd. E180-Z5812SP User Manual Read target long Send: FE 08 25 FF Send: FE 08 25 FF address Return: FB 25 0A 1C 21 FE Return: FB 25 Dec_mac FF 57 B4 14 Read transmission...
  • Page 17: Configuration Command Set

    Chengdu Ebyte Electronic Technology Co., Ltd. E180-Z5812SP User Manual Read trust center connection key Send: FE 10 38 FF Send: FE 10 38 FF Return: FB 38 Return: FB 10 TrustCentLinkKey 5A 69 67 42 65 65 41 6C 6C 69 61 6E 63 65 30 39 6.4.3 Configuration command set...
  • Page 18: Network Operation Command Set

    Chengdu Ebyte Electronic Technology Co., Ltd. E180-Z5812SP User Manual input/output status Return:FA 20 Return:FA 20 Send: FD 06 21 PwmId start/stop Send:FD 06 21 00 FF 03 65 Configure remote/local PWM Period1 Period2 duty1 02 48 FF status duty2 FF...
  • Page 19: Hex Parameter Description

    Chengdu Ebyte Electronic Technology Co., Ltd. E180-Z5812SP User Manual 6.5 HEX parameter description 6.5.1 System transmission mode Read command format: Command format Command example Send: FE 01 26 FF Send: FE 01 26 FF Return: FB 26 send_mode Return: FB 26 02...
  • Page 20: Network Node Type

    Chengdu Ebyte Electronic Technology Co., Ltd. E180-Z5812SP User Manual When non sleep terminal device receives data, it can analyze the long address of coordinator, router, terminal and other source equipment, but coordinator and router cannot analyze the long address of source equipment. Here coordinator and router are E180-ZG120A/B devices.
  • Page 21: Network Short Address

    Chengdu Ebyte Electronic Technology Co., Ltd. E180-Z5812SP User Manual Return:FA 03 Return:FA 03 Pan_id: 0x0000~0xFFFE Fixed network PAN_ID 0xFFFF Random PAN_ID Note: if the coordinator is configured as 0xFFFF, PAN_ID will be randomly selected to creat a network. If the terminal and router are configured as 0xFFFF, any PAN_ID network can be joined.
  • Page 22: Network Group Number

    Chengdu Ebyte Electronic Technology Co., Ltd. E180-Z5812SP User Manual the long address of the parent node Coor_Mac_Addr: 8 Bytes, 6.5.10 Network group number Read command format: Command format Command example Send: FE 01 09 FF Send: FE 01 09 FF...
  • Page 23: Serial Port Baud Rate

    Chengdu Ebyte Electronic Technology Co., Ltd. E180-Z5812SP User Manual 11.76 10.33 11.66 10.04 11.31 9.73 11.09 9.38 10.82 9.03 10.54 Note: The actual reference value of transmitting power. 6.5.13 Serial port baud rate Read command format: Command format Command example...
  • Page 24: Save Time Of Parent Node

    Chengdu Ebyte Electronic Technology Co., Ltd. E180-Z5812SP User Manual When the node is a sleep terminal, its functions are as follows: Sleep_time: (1~60) Sleep wake cycle is 1~6, unit (second) (61~255) Sleep wake cycle is 60+(sleep_time-60)*10, unit (second) Default value is 10, which means 10 seconds.
  • Page 25: The Maximum Number Of Attempts To Reconnect

    Chengdu Ebyte Electronic Technology Co., Ltd. E180-Z5812SP User Manual When the node is powered on, it will join the network (if there is no network) or recover the network (if there is network but no parent node) in the cycle of rejoin period. When the node detects the loss of the parent node, it will reconnect in the cycle of rejoin period.
  • Page 26: User Pwm Parameter

    Chengdu Ebyte Electronic Technology Co., Ltd. E180-Z5812SP User Manual Configuration command format: Command format Command example Send: FD 03 20 GpioId In/Out Send:FD 03 20 00 01 01 FF level FF Return:FA 20 Return:FA 20 GPIO format of peripheral configuration data (3 Byte): GpioId In/Out level。...
  • Page 27: User Adc Parameter

    Chengdu Ebyte Electronic Technology Co., Ltd. E180-Z5812SP User Manual start/stop: Start/stop channel PWM output 0xFF means to start PWM in 1mS unit, the parameter range is 0-340, and the maximum period that can be set is 340mS. When the period parameter is less than 2, the period parameter is 2, and the period is 2mS (2*1mS ).
  • Page 28: Configure All Network Parameters

    Chengdu Ebyte Electronic Technology Co., Ltd. E180-Z5812SP User Manual 6.5.22 Configure all network parameters Configuration command format: Command format Command example Send:FD 1A FE 03 FE 5B 01 0B 0A 09 54 00 00 00 0A Send:FD 1A FE all_info FF...
  • Page 29: Configure Serial Wake Up Hold Time

    Chengdu Ebyte Electronic Technology Co., Ltd. E180-Z5812SP User Manual Send: FE 01 35 FF Send: FE 01 35 FF Return: FB 35 AUX_delaytime Return: FB 35 04 Configuration command format: Command format Command example Send:FD 01 35 AUX_delaytime FF Send:FD 01 35 04 FF...
  • Page 30: Configure Trust Center Connection Key

    Chengdu Ebyte Electronic Technology Co., Ltd. E180-Z5812SP User Manual 6.5.27 Configure trust center connection key Read command format: Command format Command example Send: FE 10 38 FF Send: FE 10 38 FF Return: FB 38 Return: FB 38 TrustCentLinkKey 5A 69 67 42 65 65 41 6C...
  • Page 31: Faq

    About us Technical support: support@cdebyte.com Documents and RF Setting software download link::www.ebyte.com Thank you for using Ebyte products! Please contact us with any questions or suggestions: info@cdebyte.com ---------------------------------------------------------------------------------------------------------------------------------- Official hotline:028-61399028 Web: www.ebyte.com Address: B5 Mould Park, 199# Xiqu Ave, High-tech District, Sichuan, China...