Surge
TROUBLESHOOTING INSTRUCTIONS
Reinitialize
Follow the same steps used during the
initial setup on page 25 to reinitialize as
a starting point to trouble-shooting.
Reset Hand Control
Readout
Error Code
E07
Display is incorrectly synchronized.
The following steps move the table to
lowest height and correct the Height
Display value
1. Initialize the table using the steps on
page 25. The table should be at its
lowest point, typically with the top of
the table at a height of 18.5".
2. Simultaneously press the
buttons for approximately
3 seconds. The first digit of the
height readout should be blinking.
3. Press the ∆ or ∇ button to set the
first digit to eg.
S
4. Press the
button. The middle
number will start to blink.
5. Press the ∆ or ∇ button to set the
second digit to eg.
S
6. Press the
button. The third digit
will will begin to blink.
7. Press the ∆ or ∇ button to set the
third digit to eg.
S
8. Press the
button one final time to
apply the changes.
|
28
C6772 Rev B
Indicates Height
S
and ∆
.
1 --
.
- 8 -
.
-- 5
|
www.sitonit.net