Individual LΩGIC Product Configuration

Individual Control Personality

To set the control personality individually for the selected LΩGIC product:
1. From the menu of the selected LΩGIC product, select the Personality option.
2. Select the desired personality, from RED, GREEN, BLUE, WHITE, TW, RGB, RGBW, RGBW+D,
or FULL.
See the

Starting Address

personality.
Make sure that the starting addresses on the various products do not overlap due to the new
personality setting.
Starting Address
Each product will respond to a unique starting address from the controller. All products with the same
starting address will respond in unison. To set the starting address for the selected LΩGIC product:
1. From the menu of the selected LΩGIC product, select the DMX Address option.
2. Select the starting address (001–512).
Personality
RED
GREEN
BLUE
WHITE
TW
RGB
RGBW
RGBW+D
FULL

Network Settings

The Network Settings control the first value of the IP address and the universe of the selected LΩGIC
product.
Net Switch
To select the first value of the IP address for the selected LΩGIC product:
1. From the menu of the selected LΩGIC product, select the Network option.
2. Select the Net Switch option.
3. Select the first value of the IP address from 2.X.X.X or 10.X.X.X.
The first value of the IP address of each connected LΩGIC product MUST match that
of the LΩGIC Wall Panel 16- Port, or they will not be able to link properly.
Changing the Net Switch setting may cause the selected product to disconnect from
the LΩGIC Wall Panel 16- Port.
Universe
To assign an Art-Net™ or sACN universe to the selected LΩGIC product:
1. From the menu of the selected LΩGIC product, select the Network option.
2. Select the Universe option.
3. Set the universe, from 000–255 (for Art-Net™) or from 001–256 (for sACN).

Factory Reset

To reset the selected LΩGIC product to factory default settings:
1. From the menu of the selected LΩGIC product, select the Factory Reset option.
2. Select Yes to reset, or No to cancel.

Information

To view additional information on the status of the selected LΩGIC product:
1. From the menu of the selected LΩGIC product, select the Information option.
2. Select which information to view, from Version, IP Address, Fixture Hours, Label, Device UID,
MAC Address, and Temperature.
35
section for the highest starting address you can select for each
Channels
Highest Address
1
1
1
1
2
3
4
5
10
LΩGIC Wall Panel 16- Port User Manual Rev. 1
Products per Universe
512
512
512
512
511
510
509
508
503
Operation
512
512
512
512
256
170
128
102
51