Setup
3. Setup
AC Power
The LΩGIC Wall Panel 16- Port has an auto-ranging power supply and it can work with an input voltage
range of 200 to 240 VAC, 50/60 Hz.
To determine the product's power requirements (circuit breaker, power outlet, and wiring), use the current
value listed on the label affixed to the product's back panel, or refer to the
listed current rating indicates the product's average current draw under normal conditions.
Always connect the product to a protected circuit (a circuit breaker or fuse). Make sure the
product has an appropriate electrical ground to avoid the risk of electrocution or fire.
Never connect the product to a rheostat (variable resistor) or dimmer circuit, even if the
rheostat or dimmer channel serves only as a 0 to 100% switch.
Emergency Backup Power
To keep the LΩGIC system powered on and maintain the lighting in the case of an emergency, it is
recommended to use a battery backup UPS (Uninterruptable Power Supply) between the
LΩGIC Wall Panel 16- Port and the mains power, as well as between each POE injector and the mains
power.
This UPS can be one which is hardwired directly to the power cord included with the LΩGIC Wall Panel 16-
Port, or one with 120V Edison ports. See
AC Connections
Connection
AC Live
AC Neutral
AC Ground
LΩGIC Wall Panel 16- Port User Manual Rev. 1
AC Connections
Wire (U.S.)
Black
White
Green/Yellow
Technical
for wiring information.
Wire (Europe)
Brown
Blue
Green/Yellow
Specifications. The
Screw Color
Yellow or Brass
Silver
Green
8