Home Screen; Control Protocol; Local; Output Status - Iluminarc LOGIC User Manual

Wall panel 16-port
Hide thumbs Also See for LOGIC:
Table of Contents

Advertisement

Operation

Home Screen

The LΩGIC Wall Panel 16- Port has a home screen that shows the current control protocol, number of
connected LΩGIC products, IP address, and date as set on the internal calendar. The home screen will
also indicate if the System Clock has placed the product in Shut off mode.
To see the home screen, press <ESC/BACK> repeatedly until it shows on the display.

Control Protocol

The LΩGIC Wall Panel 16- Port works with DMX, Art-Net™, and sACN control signals. To select which
protocol to use:
1. Go to the Protocol main menu.
2. Select the desired protocol, from DMX512, ArtNet, or sACN.

Local

The Local settings include the network settings for the LΩGIC Wall Panel 16- Port as well as system
information and other general options.

Output Status

To view the status of the output ports:
1. Go to the Local main menu.
2. Select the Output Status option.
3. Select the output, from Output 1 Status to Output 32 Status.
4. View the output data:
Status: Shows Normal or Fault (if no connection or faulty connection).
Connect: Shows On (connected) or Off (not connected).
CLASS: Shows None or the type of POE connection, from 1–8.
V1, Cur 1, V2, Cur 2, and Power: electrical data in volts, milliamperes, and watts.

Net Switch

To select the first value of the IP address for the LΩGIC Wall Panel 16- Port:
1. Go to the Local main menu.
2. Select the Net Switch option.
3. Select the first value of the IP address from 2.X.X.X or 10.X.X.X.
The first value of the IP address of each connected LΩGIC product MUST match that
of the LΩGIC Wall Panel 16- Port, or they will not be able to link properly.
Changing the Net Switch setting may cause the LΩGIC Wall Panel 16- Port to
disconnect from any connected products.

Universe

To assign an Art-Net™ or sACN universe to the LΩGIC Wall Panel 16- Port:
1. Go to the Local main menu.
2. Select the Universe option.
3. Set the universe, from 000–255 (for Art-Net™) or from 001–256 (for sACN).

Password Lock

To turn the password lock on or off:
1. Go to the Local main menu.
2. Select the Password option.
3. Select from ON or OFF.
When the password lock is activated, the product will prompt for the password in order to
access the menu. Use the <MENU> knob to select and enter 123456.
LΩGIC Wall Panel 16- Port User Manual Rev. 1
Control Protocol
1/17/2024
12:08:55
Illuminarc
Logic Wall Panel
IP: 2.101.0.48
Online:
Status:
32