Priority

To select whether input from a LΩGIC Wall Controller or input from a control signal (DMX, Art-Net™, or
sACN) will take priority over the other:
1. Go to the Local main menu.
2. Select the Priority option.
3. Select from Control Panel or Signal. The selected option will have priority.

History

The LΩGIC Wall Panel 16- Port keeps a record of all LΩGIC products to which it has linked.
To view the history:
1. Go to the Local main menu.
2. Select the History option.
3. Select the List option.

Wall Con Zone

To set the zone and group of a selected Wall Con:
1. Go to the Local main menu.
2. Select the Wall Con Zone option.
3. Select either the Wall Con Zone One option or Wall Con Zone Two option.
4. Select a group from Group 1–16.
5. Select a Wall Con from Wall Con 1–4.
6. Select a device from 0–31 or select OFF to disable.

Local Information

To view general information including the firmware version, IP address, and any current errors:
1. Go to the Local main menu.
2. Select the Local Info option.
3. Select which information to view, from:
Version (current firmware version),
IP Address,
Fixture Hours (the amount of time the product has been powered on, in hours, minutes, and seconds),
Label,
Device UID,
MAC Address,
Temperature (in degrees Celsius),
Power Temperature 1–4 (in degrees Celsius), or
Warning Messages (current errors)

System Reset

To reset the LΩGIC Wall Panel 16- Port to factory default settings:
1. Go to the Local main menu.
2. Select the System Reset option.
3. Select from No or Yes.
System Clock settings will not be reset.

Match Net

To set the fixture segment to the driver segment:
1. Go to the Local main menu.
2. Select the Match Net option.
3. Select the No or Yes option.
Disconnecting Products from the LΩGIC Wall Panel 16- Port
When any linked LΩGIC product which has linked to the LΩGIC Wall Panel 16- Port is disconnected or
removed, it will trigger an error message. To remove the error message, either reconnect the product or
clear the history so the LΩGIC Wall Panel 16- Port no longer has a record of that product being linked.
To clear the history:
1. Go to the Local main menu.
2. Select the History option.
3. Select the Clear option.
4. Select from No (cancel) or Yes (clear).
33
LΩGIC Wall Panel 16- Port User Manual Rev. 1