PANEL CONTROLS
5
The blowers and automatic fuel supply are controlled from
a panel on the left-hand side of this unit. The control panel
functions are a follows.

ON/OFF SWITCH

• When pushed, the stove will automatically ignite. No
other firestarter is necessary. The igniter will stay on for at
least 10 and up to 15 minutes, depending on when Proof
of Fire is reached. The fire should start in about 5 minutes.
• The green light located above the ON/OFF button (in
the ON/OFF box) will flash during the ignition start-up
period.
• The Heat Level Advance is inoperable during the ignition
start-up period. When the green light continuously stays
on, the Heat Level Advance can be adjusted to achieve
the desired heat output.
NOTE: If the stove has been shut off, and you want to re-
start it while it is still warm, the "On/Off" button must be
held down for 2 seconds.
FUEL FEED SWITCH
• When the "Fuel Feed" button is pushed and held down,
the stove will feed pellets continuously into the burnpot.
• While the stove's auger system is feeding pellets, the
green light (in the "Fuel Feed" box) will be on.
© 2024 Breckwell
NEVER OPERATE THIS PRODUCT WHILE UNATTENDED
DO NOT USE THIS CONTROL DURING NORMAL
OPERATION BECAUSE IT COULD SMOTHER THE FIRE AND
LEAD TO A DANGEROUS SITUATION.
HIGH FAN SWITCH
• The room air fan speed varies directly with the feed rate.
The "High Fan" switch overrides this variable speed
function. It will set the room air blower speed to high at
any feed rate setting.
• When the "High Fan" button is pushed, the room air fan
will switch to its highest setting.
• When this button is pushed again, the room air fan will
return to its original setting based on the Heat Level
Advance setting.
RESET TRIM
Different sizes and quality pellet fuel may require adjustment
of the "1" feed setting on the Heat Level Advance bar
graph. This is usually a one-time adjustment based on the
fuel you are using. The "Reset Trim" button, when adjusted,
will allow for 3 different feed rate settings for the #1 feed
setting only. To adjust, simply push the "Reset Trim" button
while the stove is operating at setting "1" and watch the
bar graph.
• When the "1" & "3" light are illuminated on the bar
graph, the low feed rate is at its "lowest" setting. (approx.
0.9 pounds per hour)
• When the "1" light is illuminated on the bar graph, the
low feed rate is at its "normal" setting.
• When the "1" & "4" lights are illuminated on the bar
graph, the low feed rate is at its "highest" setting.
NOTE: When the stove is set on "1" the "Reset Trim" values
will be shown in the Heat Level Advance bar graph. For
example: if the "Reset Trim" is set to its lowest setting every
time the stove is set to low, the "1" and "3" lights will be
illuminated on the bar graph.
HEAT LEVEL ADVANCE
• This button, when pushed, will set the pellet feed rate,
hence the heat output of your stove. The levels of heat
output will incrementally change on the bar graph starting
from level "1" to "5."
NOTE: When dropping 3 or more heat level settings (4 to
1, or 5 to 2 or 1), push the "High Fan" button and allow the
room air fan to run at that setting for at least 5 minutes to
10