Breckwell SP1000E Owner’s Instruction And Operation Manual
Breckwell SP1000E Owner’s Instruction And Operation Manual

Breckwell SP1000E Owner’s Instruction And Operation Manual

Advertisement

Quick Links

Owner's Instruction and Operation Manual
Model Number:
SP1000E
Report Number: F21-690
Certified to ASTM E1509-2022, and
CAN/ULC S627:2023
Mobile Home / Transportable
Building Approved
* All Pictures In This Manual Are For Illustrative Purposes Only. Actual Product May Vary.
SAFETY NOTICE: If this heater is not properly installed, a house fire may result.
For your safety, follow the installation instructions. Never use make-shift compromises
during the installation of this heater. Contact local building or fire officials about permits,
restrictions and installation requirements in your area. NEVER OPERATE THIS PRODUCT
WHILE UNATTENDED.
CAUTION! Please read this entire manual before you install or use your new room heater.
Failure to follow instructions may result in property damage, bodily injury, or even death.
Improper Installation Could Void Your Warranty!
U.S. Environmental Protection Agency
Certified to comply with 2020 particulate
emissions standards.
© 2024 Breckwell, 227 Industrial Park Rd., South Pittsburg, TN 37380
R
Save These Instructions In A Safe Place For Future Reference.
THIS MANUAL IS SUBJECT TO CHANGE WITHOUT NOTICE.
CALIFORNIA PROPOSITION 65 WARNING:
This product can expose you to chemicals including carbon
monoxide, which is known to the State of California to cause
cancer, birth defects, and/or other reproductive harm. For
more information, go to www.P65warnings.ca.gov
854042C-1004N
Ph. 423-403-4031

Advertisement

Table of Contents
loading

Summary of Contents for Breckwell SP1000E

  • Page 1 State of California to cause emissions standards. cancer, birth defects, and/or other reproductive harm. For more information, go to www.P65warnings.ca.gov THIS MANUAL IS SUBJECT TO CHANGE WITHOUT NOTICE. © 2024 Breckwell, 227 Industrial Park Rd., South Pittsburg, TN 37380 Ph. 423-403-4031...
  • Page 2 INTRODUCTION This manual describes the installation and operation of the Breckwell, SP1000E wood heater. This heater meets the 2020 U.S. Environmental Protection Agency’s emission limits for wood heaters sold after May 15, 2020. Under specific test conditions this heater has been shown to deliver heat at rates ranging from 6,580 to 39,121 Btu/hr, 1.0 g/hr, and 75% efficiency.
  • Page 3: Installation Checklist

    Your wood stove should be installed by a qualified installer only. An NFI qualified Installer can be found at www.nficertified. org/public/find-an-nfi-pro/ For customer service, please contact your Breckwell dealer. COMMISSIONING CHECKLIST This checklist is to be completed in full by the qualified person who installs this unit. Keep this page for future reference.
  • Page 4: Installation

    • INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER. • DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST Breckwell highly recommends your stove be installed by a VENTING SYSTEM OF THIS UNIT. qualified NFI (US) or WETT (Canada) technician. To find the •...
  • Page 5: Combustion Air Supply

    UL-181-AP foil or in a valley which may cause unhealthy or nuisance tape. For mobile home/transportable building installations conditions. © 2024 Breckwell...
  • Page 6: Venting Requirements

    OPTION: To achieve a center vertical installation, a 45° elbow and a clean-out tee can be used to offset the pipe 2. Locate position of hole in wall; directly behind stove from the exhaust outlet to the rear center of the stove. exhaust vent. © 2024 Breckwell...
  • Page 7 4. Attach the L-Vent adapter, a section of pipe and clean- out tee, making sure the clean-out tee is centered in TO STOVE the chimney flue area. Use RTV, metallic tape, and a minimum of three self-taping screw at all joint connections to ensure a tight seal. © 2024 Breckwell...
  • Page 8 The illustration is only an example. Please stainless steel sheet metal screws. Seal all joints and conform to any local building codes or regulations seams around the collar. having jurisdiction before you have a qualified installer proceed with this installation. © 2024 Breckwell...
  • Page 9: Electrical Installation

    INSTALLATION The Breckwell electrical system is designed for 120V AC WARNING: with no more than 5% variation. Breckwell cannot accept YOU MAY WANT TO LOCATE ANY UTILITIES OR responsibility for poor performance or damage due to OBSTACLES INSIDE THE WALL BEFORE ATTEMPTING THIS inadequate voltage.
  • Page 10: Operation

    1, or 5 to 2 or 1), push the “High Fan” button and allow the • While the stove’s auger system is feeding pellets, the room air fan to run at that setting for at least 5 minutes to green light (in the “Fuel Feed” box) will be on. © 2024 Breckwell...
  • Page 11: Manual Mode

    CAUSE SKIN BURNS. TO SWITCH BETWEEN ANY OF THE THREE MODES, THE STOVE MUST BE SHUT OFF, THE NEW MODE SELECTED This heater is designed to burn only PFI Premium grade AND THE STOVE RESTARTED. pellets. DO NOT BURN: © 2024 Breckwell...
  • Page 12: Proper Fuel

    • The damper may need to be closed during startup. prevents proper pellet feed. Burning wood in forms other • DO NOT add pellets to the burn pot by hand. © 2024 Breckwell...
  • Page 13: Opening Door

    “3” light on the bar graph will flash and the “On/Off” light will go off. To re-start, refill hopper and press OPEN “Fuel Feed” button until pellets begin to fall into burnpot. Press “On/Off” button. © 2024 Breckwell...
  • Page 14: Interior Chambers

    B. In case of a malfunctioning convection blower, the high- and vacuum out any accumulated ash. This should be temperature thermodisc will automatically shut down done at least once per month or more frequently if large the auger, preventing the stove from overheating. © 2024 Breckwell...
  • Page 15: Maintenance

    If creosote has accumulated, it should be removed to reduce the risk of a © 2024 Breckwell...
  • Page 16: Blower Motors

    5. Vacuum to remove ashes from the burn chamber interior temperature paint. and the burnpot shell. WARNING: Make sure ashes are cool to the touch before using a vacuum (see “Vacuum Use”). © 2024 Breckwell...
  • Page 17: Removal And Replacement Of Broken Door Glass

    DO NOT INSTALL IN AN ALCOVE 200 mm (8 in) beyond the appliance on other sides, shall DO NOT INSTALL IN ANY FIREPLACE be protected by a continuous, durable, non-combustible © 2024 Breckwell...
  • Page 18: Troubleshooting Guide

    (you may want to remove the hose entirely off the stove and the air switch first and make sure it is clear). If you hear a click, the air switch is working. BE CAREFUL! TOO MUCH VACUUM CAN DAMAGE THE AIR SWITCH. © 2024 Breckwell...
  • Page 19 Remove the control board. On the back, there is one fuse. If it appears to be bad, blown. replace it with a 5 Amp 125 Volt fuse. Plug the stove back in and try to run the unit. © 2024 Breckwell...
  • Page 20 Remove the auger motor from the auger shaft and try to run the unit. If the motor will Bad auger motor. turn, the shaft is jammed on something. If the motor will not turn, the motor is bad. © 2024 Breckwell...
  • Page 21 “GLASS ‘SOOTS’ UP AT A VERY trim setting for the low feed rate. If the stove is being burned on one of the two lower FAST RATE” only. settings, advance to the next trim setting and try burning the stove. © 2024 Breckwell...
  • Page 22 All joints should be properly sealed. Also, clean your stove following instructions in the “Maintenance” section of this manual. If problem persists, contact your dealer. © 2024 Breckwell...
  • Page 23: Electrical Diagram

    Other information that may be needed would be the part number and part description of the item(s) in question. Part numbers and descriptions can be found in the “Repair Parts” section of this manual. Once this information has been gathered you can contact your Breckwell dealer or visit www.Breckwell.com Model Information Model Number Dealer’s Name...
  • Page 24: Replacement Parts

    REPLACEMENT PARTS © 2024 Breckwell...
  • Page 25 88100 Exhaust Blower Gasket 893551 (Optional) Burnpot Extender IN ORDER TO MAINTAIN WARRANTY, COMPONENTS MUST BE REPLACED USING BRECKWELL PARTS PURCHASED THROUGH YOUR DEALER OR DIRECTLY FROM BRECKWELL. USE OF THIRD PARTY COMPONENTS WILL VOID THE WARRANTY. © 2024 Breckwell...
  • Page 26 #12 X .75 Socket HD Cap 83633 Screw IN ORDER TO MAINTAIN WARRANTY, COMPONENTS MUST BE REPLACED USING BRECKWELL PARTS PURCHASED THROUGH YOUR DEALER OR DIRECTLY FROM BRECKWELL. USE OF THIRD PARTY COMPONENTS WILL VOID THE WARRANTY. © 2024 Breckwell...
  • Page 27 ITEMS DEFINED © 2024 Breckwell...
  • Page 28: Service Record

    Date: _____________________ Engineer Name: _________________________________ Engineer Name: _________________________________ License No.: _____________________________________ License No.: _____________________________________ Company: ______________________________________ Company: ______________________________________ Telephone No.: __________________________________ Telephone No.: __________________________________ Stove Inspected: Chimney Swept: Stove Inspected: Chimney Swept: Items Replaced: __________________________________ Items Replaced: __________________________________ © 2024 Breckwell...

Table of Contents