OPERATION

NEVER OPERATE THIS PRODUCT WHILE UNATTENDED
PANEL CONTROLS
The blowers and automatic fuel supply are controlled from
a panel on this unit. The control panel functions are as
follows.

ON/OFF SWITCH

• When pushed the stove will automatically ignite. No
other firestarter is necessary. The igniter will stay on for at
least 10 and up to 15 minutes, depending on when Proof
of Fire is reached. The fire should start in about 5 minutes.
• The green light located above the On/Off button (in the
On/Off box) will flash during the ignition start-up period.
• The Feed Rate Advance is inoperable during the ignition
start period. When the red light continuously stays on
the Feed Rate Advance can be adjusted to achieve the
desired heat output.
NOTE: If the stove has been shut off, and you want to re-
start it while it is still warm, the "On/Off" button must be
held down for 2 seconds.
FUEL FEED SWITCH
CAUTION:
DO NOT USE THIS CONTROL DURING NORMAL
OPERATION BECAUSE IT COULD SMOTHER THE FIRE AND
LEAD TO A DANGEROUS SITUATION.
• When the "Fuel Feed" button is pushed and held down
the stove will feed pellets continuously into the burnpot.
• While the stove's auger system is feeding pellets the
amber light (in the "Fuel Feed" box) will be on.
HIGH FAN SWITCH
• The room air fan speed varies directly with the feed rate.
The "HIGH FAN" switch overrides this variable speed
function. It will set the room air blower speed to high at
any feed rate setting.
• When the "High Fan" button is pushed the room air fan
will switch to its highest setting.
• When this button is pushed again the room air fan will
return to its original setting based on the Feed Rate
Advance setting.
RESET TRIM
Different size and quality pellet fuel may require adjustment
of the "1" feed setting on the Feed Rate Advance bar graph.
This is usually a one-time adjustment based on the fuel you
are using. The "Reset Trim" button when adjusted will allow
for 3 different feed rate settings for the #1 feed setting only.
To adjust simply push the "Reset Trim" button while the stove
is operating at setting "1" and watch the bar graph.
• When the "1" and "3" lights are illuminated on the bar
graph the low feed rate is at its "lowest" setting. (approx.
0.9 pounds per hour)
• When the "1" light is illuminated on the bar graph the
low feed rate is at its "normal" setting.
• When the "1" & "4" lights are illuminated on the bar
graph the low feed rate is at its "highest" setting.
NOTE: When the stove is set on "1" the "reset trim" values
will be shown on the Feed Rate Advance bar graph. For
example if the Reset Trim is set to its lowest setting every
time the stove is set to low the "1" and "3" lights will be
illuminated on the bar graph.
HEAT LEVEL ADVANCE
• This button when pushed will set the pellet feed rate, hence
the heat output of your stove. The levels of heat output will
incrementally change on the bar graph starting from level
"1" to "4". NOTE: When dropping more than 2 heat
level settings (i.e. 4 to 1) push the 'High Fan' button and
allow the room air fan to run at that setting for at least 5
minutes to prevent the stove from tripping the high temp
thermodisc. If the high temp thermodisc does trip (see
"Safety Features" section of this manual).