5. Position the stove, adhering to the clearances.
6. Measure and build chimney top plate. Cut out holes for
chimney pipe, and if used the outside air pipe. Install
and seal with non-hardening mastic to prevent water
leakage. Install vent cap.
3"
(77 mm)
NOTE: FOLLOW
METAL CHIMNEY
INSTALLATION
INSTRUCTIONS
6"
(153 mm)
HEARTH
THROUGH SIDE OF MASONRY CHIMNEY
1. Position the stove, adhering to the clearances. Mark
the center of the hole where the pipe is to pierce the
masonry chimney.
2. It will be necessary to break out the masonry around
the location of the pipe center mark. Use a 4" (102
mm) diameter hole for 3" (77 mm) pipe and 5" (127
mm) diameter hole for 4" (102 mm) pipe.
3. Measure and build chimney top plate. Cut out holes for
chimney pipe, and if used, the outside air pipe.
4. Install the tee on the bottom of the vertical pipe system
and lower it down the chimney until the center branch
of the tee is level with the center of the hole in the
masonry as shown.
5. Install and seal the top plate from step 3 with non-
hardening mastic. Slip the storm collar over the pipe,
and while holding the pipe at the proper elevation,
affix the collar with a minimum of 3-1/4" (83 mm)
stainless steel sheet metal screws. Seal all joints and
seams around the collar.
© 2024 Breckwell
6"
(153 mm)
TOP PLATE (SEAL
TO CHIMNEY TOP
WITH NON-
HARDENING
MASTIC)
EXTENSION TO
CHIMNEY TOP
REQUIRED.
3" OR 4" STAINLESS
STEEL SINGLE WALL
PIPE OR FLEX PIPE.
BLANKING PLATE
(SEAL WITH NON-
HARDENING MASTIC).
3" OR 4" STAINLESS
STEEL FLEX PIPE.
OPTIONAL OUTSIDE AIR
CLEAN-OUT-TEE (TYPE L)
OR 90 DEGREE ELBOW
6. Connect the horizontal pipe by pushing it through the
hole in the masonry and lining it up with the branch in
the tee. Push the pipe into the tee while twisting it to
lock it into the tee.
7. If desired, once the horizontal pipe is in place, the
space between the pipe and masonry may be filled
with high-temperature grout.
8. Install the trim collar. An adjustable pipe length and
adapter may be needed to finish the connection to the
stove.
3"
(77 mm)
NOTE: FOLLOW
METAL CHIMNEY
INSTALLATION
INSTRUCTIONS
OPTIONAL
OUTSIDE AIR
TRIM COLLAR
VENTING YOUR PELLET STOVE INTO AN
EXISTING CLASS A 6" CHIMNEY SYSTEM
IMPORTANT:
IF YOU ARE INSTALLING YOUR PELLET STOVE AS A
REPLACEMENT TO AN EXISTING WOOD STOVE, YOU
CAN INSTALL YOUR PELLET STOVE USING THE EXISTING
CLASS A 6" VENTING SYSTEM.
1. You must have the existing chimney system cleaned
and/ or inspected by a qualified chimney sweep before
proceeding with the installation of your pellet stove.
2. To the right is an example of an installation using part
number 860001, 3-6" transition into 6" connector
pipe. The illustration is only
conform to any local building codes or regulations
having jurisdiction before you have a qualified installer
proceed with this installation.
8
INSTALLATION
6"
(153 mm)
TOP PLATE (SEAL
TO CHIMNEY TOP
WITH NON-
HARDENING
MASTIC)
EXTENSION TO
CHIMNEY TOP
REQUIRED
L-VENT OR OPTIONAL
3 OR 4 " STAINLESS
STEEL SINGLE WALL
PIPE OR FLEX PIPE.
PIPE ADAPTER
CLEAN-OUT-TEE
(TYPE L)
an example. Please