Opening Door - Breckwell SP1000E Owner’s Instruction And Operation Manual

Table of Contents

Advertisement

OPERATION
NOTE: During the first few fires, your stove will emit an odor
as the high-temperature paint cures or becomes seasoned to
the metal. Maintaining smaller fires will minimize this. Avoid
placing items on the stovetop during this period because the
paint could be affected. Attempts to achieve heat output
rates that exceed heater design specifications can result in
permanent damage to the heater.
AUTOMATIC IGNITOR
1. Fill hopper and clean burn pot.
2. Press "On/Off" button. Make sure green light comes
on.
3. The damper should be completely closed or open no
more than 1/4 of the way during start-up. This will vary
depending on your installation and elevation. Once
fire is established adjust for desired flame increasing
the amount the damper is open as the heat setting is
increased (see "Damper Control").
4. Adjust feed rate to desired setting by pressing "Heat
Level Advance" button.
OPTIMAL OPERATION
This pellet stove has been certified by the US EPA to meet
strict 2020 guidelines. To ensure this unit produces the
optimal minimal emissions, it is critical to follow the following
guidelines. To achieve a "high burn", your stove should be
set on setting 5 with the damper fully open. To achieve a
"medium burn", your stove should be set on setting 2 with
the damper closed. To achieve a "low burn", your stove
should be set on setting 1 with the damper closed. Settings 3
and 4 will give you a higher heat output above the medium
setting. If the door is opened while the stove is in operation,
it must be closed within 30 seconds or the stove will shut
down. If the stove shuts down, push the "On/Off" button to
restart your stove. The stove will have to fully shut down and
turn off before you will be able to restart the stove.
OPEN
CLOSED

OPENING DOOR

If the door is opened while the stove is in operation it must
be closed within 30 seconds or the stove will shut down. If
the stove shuts down push the "On/Off" button to re-start
your stove. The stove will have to fully shut down and turn
off before you will be able to restart the stove.
• DO NOT OPERATE YOUR STOVE WITH THE VIEWING
DOOR OPEN. THE AUGER WILL NOT FEED PELLETS
UNDER THESE CIRCUMSTANCES AND A SAFETY
CONCERN MAY ARISE FROM SPARKS OR FUMES
ENTERING THE ROOM.
• THE FEED DOOR MUST BE CLOSED AND SEALED
DURING OPERATION.
ROOM AIR FAN
When starting your stove the Room Air Fan will not come
on until the stove's heat exchanger warms up. This usually
takes about 10 minutes from start-up.
IF STOVE RUNS OUT OF PELLETS
The fire goes out and the auger motor and blowers will
run until the stove cools. This will take 30 to 45 minutes.
After the stove components stop running, the "On/Off" and
the Bar Graph lights stay on for 10 minutes. After the 10
minutes, the "3" light on the bar graph will flash and the
"On/Off" light will go off. To re-start, refill hopper and press
"Fuel Feed" button until pellets begin to fall into burnpot.
Press "On/Off" button.
13
CAUTION:
© 2024 Breckwell

Advertisement

Table of Contents
loading

Table of Contents