Parameter List
PNU
Parameter Name in OP1
*:conf-P
Description
P557
Src3 OFF2 (coast)
*
Source 3 of the OFF2 control command (control word 1, bit 1)
22DHex
See P555 for description
B/R parameter
Type=L2; PKW: PKW format(HEX)=param.value
P561
Src InvRelease
*
Source for the inverter enable command (control word 1, bit 3)
231Hex
See Section "Control word" for details
Parameter values: 0: Disable inverter
Other values:
B/R parameter
Type=L2; PKW: PKW format(HEX)=param.value
P565
Src1 Fault Reset
*
Source 1 of "Acknowledge" control command (control word 1,
235Hex
bit 7)
See Section "Control word" for details
Parameter values: 0:
Other values:
Note: The "Acknowledge" control command is edge-triggered.
B/R parameter
Type=L2; PKW: PKW format(HEX)=param.value
P566
Src2 Fault Reset
*
Source 2 of "Acknowledge" control command (control word 1,
236Hex
bit 7)
See P565 for description
B/R parameter
Type=L2; PKW: PKW format(HEX)=param.value
P567
Src3 Fault Reset
*
Source 3 of "Acknowledge" control command (control word 1,
237Hex
bit 7)
See P565 for description
B/R parameter
Type=L2; PKW: PKW format(HEX)=param.value
P568
Src Jog1 ON
*
Source for the Inching 1 setpoint (control word 1, bit 8)
238Hex
See Section "Control word" for details
Parameter values: 0:
Other values:
B/R parameter
Type=L2; PKW: PKW format(HEX)=param.value
12-18
1: Automatically when delay timers run
down
See permissible settings in Section "Control
word"
(process data connections of control word)
No source selected
1:
Illegal setting
1003:
Digital input 3 on CUSA
See permissible settings in Section "Control
word"
(process data connections of control word)
No inching
1:
Illegal setting
2001:
SST1, word 1 bit 8
See permissible settings in Section "Control
word"
(process data connections of control word)
Range
[Unit]
Value Texts
1 to 5001
PZD Gr.: 0
0 to 5001
PZD Gr.: 0
0 to 5001
PZD Gr.: 0
0 to 5001
PZD Gr.: 0
0 to 5001
PZD Gr.: 0
0 to 5001
PZD Gr.: 0
6SE7087-6CX86-2BA1
Operating Instructions SIMOVERT MASTERDRIVES AFE
01.2004
# of Indices
read:
_/_
Factory
write:
_/_
Settings
2
2 / BR
i001=1
2 / BR
i002=1
2
3 / BR
i001=1
3 / BR
i002=1
2
2 / BR
i001=0
2 / BR
i002=1003
2
2 / BR
i001=0
2 / BR
i002=0
2
2 / BR
i001=2001
2 / BR
i002=2001
2
2 / BR
i001=0
2 / BR
i002=0