Summary of Contents for Siemens SIMATIC RTLS PCB OEM PULSE

  • Page 1 SIMATIC RTLS Localization systems SIMATIC RTLS PCB OEM PULSE (6GT2700-8AF03) Manual 10/2018 C79000-G8976-C552-01...
  • Page 2 Notices in the relevant documentation must be observed. Trademarks All names identified by ® are registered trademarks of Siemens AG. The remaining designations in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
  • Page 3 Tel.: +49 - (0)371 - 45 00 48-0 Fax.: +49 - (0)371 - 45 00 48-11 www.agilion.de service@agilion.de Management: Andreas Werner Johannes Waldhör Sven Sieber HR B 21249 Chemnitz VAT ID no.: DE236591552 SIMATIC RTLS PCB OEM PULSE Manual, 10/2018, C79000-G8976-C552-01...
  • Page 4: Table Of Contents

    Wireless ..............................8 Environment .............................. 8 Approvals ..............................9 EU declaration of conformity ........................9 RoHS ................................. 9 RED ................................. 10 3.3.1 Protection of health and safety ....................... 10 Recycling and disposal ..........................11 SIMATIC RTLS PCB OEM PULSE Manual, 10/2018, C79000-G8976-C552-01...
  • Page 5: Dimensions, Connections And Leds

    1 Dimensions, connections and LEDs 1.1 Dimensions The antenna is connected to the PCB via a 5 cm long U.FL cable. The contacts used are P3 on the PCB and P1 on the antenna. Drill holes SIMATIC RTLS PCB OEM PULSE Manual, 10/2018, C79000-G8976-C552-01...
  • Page 6: Displays

    Indicates radio activity Transponder is not in operation 1.3 Solder contact P4 Description/function Grounding Rx - Input on the transponder, 3.3 V Tx - Output on transponder, 3.3 V Supply voltage, 3.3 V SIMATIC RTLS PCB OEM PULSE Manual, 10/2018, C79000-G8976-C552-01...
  • Page 7: P1 Connector

    Rx - Input on the transponder, 3.3 V Tx - Output on transponder, 3.3 V Grounding Supply voltage, VCC, 3.3 V ±100 mV 1.5 P2 connector Internal interface for production and manufacturing test, do not use. SIMATIC RTLS PCB OEM PULSE Manual, 10/2018, C79000-G8976-C552-01...
  • Page 8: Technical Specifications

    44 x 24 x 7.5 mm Antenna dimensions 38 x 20 x 3 mm Weight Approx. 10 g Temperature range 0 to +50 ℃ Method of securing PCB: 3 screws, Ø 1.7 mm Antenna: provided by customer SIMATIC RTLS PCB OEM PULSE Manual, 10/2018, C79000-G8976-C552-01...
  • Page 9: Approvals

    2011/65/EU on the restriction of the use of certain hazardous substances in electrical and electronic equipment. Applied standard: • EN 50581 Technical documentation for the assessment of electrical and electronic products with respect to restriction of hazardous substances SIMATIC RTLS PCB OEM PULSE Manual, 10/2018, C79000-G8976-C552-01...
  • Page 10: Red

    Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity for residential, commercial and light-industrial environments • EN 61000-6-2 Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity for industrial environments SIMATIC RTLS PCB OEM PULSE Manual, 10/2018, C79000-G8976-C552-01...
  • Page 11: Recycling And Disposal

    Do not dispose of the products at public disposal sites. For environmentally compliant recycling and disposal of your electronic waste, please contact a company certified for the disposal of electronic waste or your Siemens representative. Note the different national regulations.