Inverter states and alarms

13. Inverter states and alarms
The inverters have an LED light on the front dial, and an LED on the communications dongle. These lights indicate
the state of the inverter and the communications, and the possible existence of alarms.

13.1. Inverter states (lighting on front dial)

LED color
Green
Blue
Red
13.2. Inverter communication states (lighting on communications
dongle)
LED color
Blue

13.3. Alarms

INFO
See the guide ACL0000IMC01 which lists the alarms and how to resolve any problems that may arise in
the installation and during operation. To download the guide, go to the INGECON SUN Training website
(www.ingeconsuntraining.info).
ACL2013IQM01_ - Installation and Operation Manual
LED type lighting
Flashing
On
On
Flashing
On
LED type lighting
Flashing
On
Switched off
Status
Attempting to connect or reconnect to the electricity grid
(standby)
Inverter connected to the electricity grid
Operating with limited power
Inverter disconnected from the electricity grid due to an
active incident
Inverter disconnected from the electricity grid due to
manual shutdown
Status
Inverter trying to establish communication
Inverter with active communication
Inverter without communication