Setup Options

The following setup options are available on the Open Pos Adjust Setting menu. The the joystick to select each
option and set the values. (Figure 14)
y OPEN SPEED:
Speed at which the door opens.
y MAX OPEN FORCE:
Force exerted by the motor to open the door.
y OPEN POSITION ADJUST:
Once the open position has been set, the door can be
adjusted +/- 5° without having to rehome the unit.
y OPEN START FORCE:
Force exerted by the motor at the start of the opening
cycle to help overcome stack pressure or latch device.
y OPEN STALL FORCE:
Force exerted when the door is slowed to a stop while
opening, with 1 being lightest and 10 being strongest.
Measure the door force to ensure compliance with
applicable standards and codes.
y ADJUST HOLD OPEN:
Time the door is held at the open position when ON/OFF/
HO switch is in ON position.
y HOLD OPEN FORCE:
Force exerted to hold the door in the max open position.
This can be adjusted to overcome stack pressure, wind,
or other forces pushing on the door.
y OBST DET SENS:
Amount of time the door will push against an
obstruction before stalling or moving in the opposite
direction.
8
Max Open Force
Figure 14
Initial Operator setup is now complete.
Continue setup with "Connections" on page 12.
Copyright © 2023, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or in part
without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
6000 Series Programming Instructions
y OPEN DELAY 1:
Time before the door begins to open once activation
has been received.
y OPEN DELAY 2:
Time before door begins to open once activation has
been received. Part of Vestibule functionality.
y PUSH & GO:
As the door is manually opened, the operator
'senses' movement and opens the door to the full-
open position.
y OBSTR DURING CLOSE:
Door will reverse to the open position if it hits an
obstruction while closing.
y NO OBSTR NEAR OPEN:
Used with the door mounted presence sensor. The
operator will ignore an obstruction input from the
sensor in last 30 degrees of opening.
y NO OBSTR NEAR CLOSE:
Used with the door mounted presence sensor. The
operator will ignore an obstruction input from the
sensor in last 10 degrees of closing.
y ENERGIZE <20°:
24V outputs will change state when the door is 20
degrees from close after a manual or automatic
cycle.