6000 Series Programming Instructions

Adjust Opening and Closing Position

A. Access the Open Pos Adjust menu.
Use the joystick to scroll through and adjust the electrical
settings for opening and closing the door. (Figure 13).
For a list of options, refer to Setup Options on page 8.
NOTE: Latch, Sweep, and Backcheck valves are adjusted
during the initial installation. Refer to the installation
instructions provided with the operator.
Speed/Force and Timing/Location settings must be
adjusted to meet ANSI BHMA A159.19 (American National
Standard for Power Operated Doors) requirements for
opening and closing based on door weight and width.
Refer to the information below.
"D"
Door Leaf Width
Inches (mm)
*30" (762)
36" (914)
42" (1067)
48" (1219)
* Check applicable Building Codes for clear width requirements in the Means of Egress. See Appendix for additional door weights.
Backcheck at 60°
Table I plus 2 seconds
If the door opens more than 90 degrees, it shall continue at the same rate as backcheck speed. Matrix values are in seconds.
NOTE: To determine minimum times from close to full open, the operator shall be adjusted as shown in the chart.
Backcheck occurring at a point between positions in Table II shall use the lowest setting. For example, if the backcheck
occurs at 75 degrees, the full open shall be the time shown in Table I plus 1.5 seconds.
Doors of other weights and widths can be calculated using the formula:
T = D ÖW / 133 in US Units
Where: T = Time, seconds
D = Door width, inches (mm)
W = Door weight, lbs. (kg)
The values for "T" (time) have been rounded up to the nearest half second. These values are based on a kinetic energy of
1.25 lbf-ft (1,86 kg/m).
Copyright © 2023, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or in part
without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
80-9360-1043-020 Rev 2 10/23
Minimum Opening Time to Backcheck or 80° (whichever occurs first) and
Minimum Closing Time from 90° to Latch or 10° (whichever occurs first)
100 (45.4)
125 (56.7)
3.0 sec
3.0 sec
3.0 sec
3.5 sec
3.5 sec
4.0 sec
4.0 sec
4.5 sec
Total Opening Time to 90°
T = D ÖW / 2260 in SI (metric) Units
Backcheck
Location
Table I
"W" Door Weight in Pounds (kg)
150 (68.0)
3.0 sec
3.5 sec
4.0 sec
4.5 sec
Table II
Backcheck at 70°
Table I plus 1.5 seconds
Open Speed
6:
---
Figure 13
Latch
Location
175 (79.4)
3.0 sec
4.0 sec
4.5 sec
5.0 sec
Backcheck at 80°
Table I plus 1 second
Sweep
Speed
200 (90.7)
3.5 sec
4.0 sec
4.5 sec
5.5 sec
7