Input Connections (Default)

Use the green 2-position connectors on the control board
to install any necessary inputs. (Figure 33)
NOTE: Inputs can be customized. The operator has
several inputs which can be wired to external switches,
sensors, or dry contacts. The function of each input is
selectable depending on the installation.
To restore the operator inputs to factory defaults, select
Restore Defaults.
Activation 1
Momentary contact closure of this input cycles the door
through an automatic open / close cycle.
(Tied to Open Delay 1)
Activation 2
Momentary contact closure of this input cycles the door
through an automatic open / close cycle.
(Tied to Open Delay 2)
Executive Mode
Activation signal on this input opens the door keeps it
open until either a second signal is received or the door is
manually moved in closing direction.
Emergency Interface Relay
Continuous contact closure of this input puts operator in
a passive closer mode, where door functions as a typical
door closer and accepts no activations. Once contact is
removed, unit goes back to operator mode.
Blow Open
If 3-Position switch is in On position, the door opens
when signal is received from alarm system allowing air or
smoke to flow through opening. The door will stay open
until signal from alarm system is stopped. If the door is
pulled away from open position, operator will go back to
open.
Blow Open Override
With 3-Position switch in On or Off position, the door
opens at set position until power is turned off.
Obstruction 1
Contact closure of this input while door is closing triggers
operator to return to open position. This is used with
presence sensors mounted to closing side of a door to
prevent door from hitting an obstruction.
Copyright © 2023, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or in part
without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
80-9360-1043-020 Rev 2 10/23
Figure 33
Obstruction 2
Contact closure of this input while door is opening
triggers operator to stall. If contact is not removed after
10 seconds of closure, operator will return to closed
position. This is used with presence sensors mounted
to opening side of a door to prevent door from hitting
an obstruction.
Outside Push Button Disable
When this contact is closed, the outside push button is
disabled (connected to ACTIVATION 2 inputs(s)).
BEA 585 Presence Sensor
A BEA type 585 presence sensor may be connected
to the "SENSOR" connector on the top circuit board
of the operator using cable supplied with sensor. The
sensor must be attached to the frame according to the
BEA factory instructions and can be powered with a
separate power supply or with the power supply built
into the 6000 operator. No additional configuration
is required. See the installation instructions for more
detail.
BEA Sensor
Input Connectors