(change factory pre-wiring to illustration below - move NO to NC on controller)
+
Electromagnetic
Lock
OR
+
Electric Strike 24VDC
y The door is normally closed and latched.
y Activating the switch will unlock the electric strike or mag
lock and the door will open automatically. The door will
close after the hold open time delay has expired.
y The door will remain unlocked during a power failure.
22

24VDC Fail Safe Electric Strike or Electromagnetic Lock

Copyright © 2023, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or in part
6000 Series Programming Instructions
y Activation can be a wall switch, card reader, key switch,
etc (Normally open momentary dry contacts).
y Current draw at the Power Outputs not to exceed 1.3A.
y To turn on the relay (Relay 2), Latch Retraction (Refer to
Output Connections on page 12) and/or Open Delay
(Refer to Setup options on page 8), each feature
must be turned on using adjustment procedures.