Wiring Options - Assa Abloy NORTON RIXSON 6021 Series Installation Instructions Manual

Power operator
Table of Contents

Advertisement

Wiring Options

Factory Pre-Wiring of Connections and Incoming Wiring
To connect wiring:
For Incoming 120VAC and 24VDC for accessories
1. For 20 - 10 AWG wire
2. Strip end of wire 1/4 inch
3. Insert wire into appropriate position as shown and
use flat head screw driver to secure
Controller Error Codes
Error Code
Short Circuit
Temperature Trip
Over Voltage
Under Voltage
Aux 1 Stuck
Aux 2 Stuck
Aux 3 Stuck
Comm Error
Presence Detect
Drive Disabled
14
6021/6031 Series (Push Side) Power Operator
A short was sensed on the motor outputs
Power module reached 200°F or greater (too much load in too hot ambient condition)
Line Voltage has reached 145VAC or greater
Line Voltage has dropped below 80VAC
Activation device connected to Aux 1 is sending constant signal
Activation device connected to Aux 2 is sending constant signal
Activation device connected to Aux 3 is sending constant signal
No communication between top and bottom controller boards. Boards not functioning properly
Device connected to Presence Detect and was activated
Selector mode switch on end cap closest to latch is in "OFF" position
Copyright © 2019, 2023, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole
or in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
Approved 2023-01-24
For Low Voltage / Dry Contacts on Inverter
1. For 24 - 16AWG wire
2. Strip end of wire 3/8 inch
3. Use flat head screw driver to push down on white
button above desired location, insert wire, release
button. Pull on wire to confirm installed properly.
Incoming wiring
(Supplied by others)
Description
80-9360-1027-020 Rev 5 01/23