Jofemar argos Series Instruction Manual page 25

Table of Contents

Advertisement

• Recovery motor, faulty.
• Coin tube XX, incorrect.
• Lock coil XX, faulty. (Coil of the safety lock of the refund trolley, faulty).
• Tube coins XX, unprogrammed.
Pressing button 2 all the faults of the compact X-10 are reseted.
Pressing button 6 and after the button 1 the compact X-10 make a test of 30 cycles.
OP_54 COIN CHECKING.
In this address we obtain the value and way (tube, cash box or why the coin is not
accepted) of the inserted coins. In this option all the coins go to the coin refund.
On the display can be appears the following messages:
• Coin XXX pts, cash box.
• Coin XXX pts, tube YY.
• Coin, unknow.
• Coin XXX pts, machine inh. (Machine inhibites the coin).
• Coin XXX pts, validator inh. (Validator inhibites the coin).
• Coin XXX pts, value 0 inh.
10).
• Coin XXX pts, ref. troll. inh.
• Coin XXX pts, X-10 inhibit.
OP_55 CODE OF COUNTRY.
In this address the code of the country recorded in the X-10 is displayed.
MNP45GBV02
(The coin have value 0 in the coin table of X-
(Refund trolley of the X-10 in bad position).
(X-10 inhibites the coin).
27/03/04 Rev. 1