OP_35 PROGRAMMING MONETARY UNIT.
Pressing refund makes the message PROG. MONETARY UNIT "PTS" appear, with
the cursor placed on the first letter.
In order to programme a new monetary unit, the following buttons are used:
- Button 1: Selects a character in upwards option.
- Button 2: Selects a character in downwards option.
- Button 3: Deletes the character on which the cursor is placed.
- Button 4: Moves the cursor on to the following character.
In order to quit this option, press the programming button.
The currency appears on the display in the context of prices, credit and money
counts.
OP_36 PROGRAMMING THE LANGUAGE.
Pressing refund displays the currently programmed language.
Pressing refund again selects the desired language: Spanish, English, German,
Portuguese, French, Italian. After having programmed the language all massages on
the display appear in that language.
OP_37 PITIDO (Beep).
Pressing refund displays the currently programmed option.
Pressing refund again selects PITIDO (Beep) Inhibited or Enable.
If this option is enable the PITIDO (Beep) when a button is pressed or if a coin is
accepted you will hear a pitido (beep).
OP_ 50 PROGRAMMING OF COINS IN TUBES.
Pressing refund button on the display appears "Tube 1, Value: 25", to change the tube
press the button 1 and to change the coin value press the button 2. If it is desired to
program no coin in a tube, program the value "not programmed" as the coin selected
in that tube.
Before changing the coin selected to fill a tube, check you have selected the correct
tube size.
If we observe that the display is flashing, this indicates that there is a possibility that
the count does not coincide with the actual number of coins in this tube.
OP_ 52 PROGRAMMING OF MAXIMUMS IN TUBES.
Pressing refund button on the display appears "Tube 1, Maximum: 55", to change the
tube press the button 1, to change the maximum of 1 in 1 press the button 2, to
change the maximum the 5 in 5 press the button 3 and to reset the maximun press
the button 4.
OP_53 X-10 FAULTS CHECKING.
Pressing refund button on the display appears the errors in the X-10.
On the display can be appears the following messages:
• X-10, correct.
• Separator coil XX, faulty.
• Refund coil XX, faulty.
• Photo-sensor XX, faulty.
• Validator, synchr. error. (Synchronism error).
• Validator, out error.
• Refund motor, faulty.
MNP45GBV02
(Photo-sensor or T10 coil broken).