10 Examples of installation and connection with an AURIGA M/T-A outdoor unit
Tab.44
Access path
Parameter
CIRCA >
MaxZoneTFlowSetpoi
21.7
Parameters, counters,
nt
signals > Settings
CP000
Zone Function
CP020
CIRCA > Heating
Slope:
21.7
Curve
CP230
Tab.45
Access path
23.5
Air Src Heat pump >
Parameters, counters,
signals
> Settings
60
On
Description
Maximum Flow Temperature setpoint
zone
Functionality of the zone
Value of the heating curve gradient.
On
Parameter
Buffer tank
HP086
Buffer tank hyst
HP087
Boiler pump function
AP102
3. Configure the radiator circuit parameters (CIRCA).
4. Configure the low loss header parameters.
Description
Activation of hydraulic management mode
for the configuration with a low-loss header,
or for a buffer tank connected as a low-loss
header
Temperature hysteresis to start or stop
heating the buffer tank
Configuration of the boiler pump as zone
pump or system pump (feed lowloss
header)
OFF: No
ON: Yes
5. If necessary, configure the hybrid operating mode.
6. Setting up the backup boiler.
Adjustment required
75 °C (factory setting)
Adjust the temperature as required.
Direct (factory setting)
This setting does not enable cooling.
1.5 (for a radiator circuit)
Adapt the values of the heating curve
in order to obtain optimum comfort.
Adjustment required
Yes
Default value: 3 °C
Do not modify.
No