8 Settings
Parameter
Service hours (AP009)
Service hours mains (AP011)
8.5

Configuring the heating circuit

8.5.1

Setting the circuit function

Tab.8
Access path
> Installation Setup > CIRCA > Settings > Zone Function (CP020)
Value
Disable
Direct
Mixing Circuit
Swimming pool
High Temperature
Fan Convector
DHW tank
Electrical DHW
Time Program
ProcessHeat
8.5.2

Setting the heating curve

Fig.42
14 : 23 Zone setup
Heating curve
Slope: 1.5
Max: 90˚C
50˚C;0˚C
Base: 20˚C
28
Description
Compressor operating hours before a maintenance message is sent
Operating hours switched on before a maintenance message is sent
Set the circuit function based on the constituent components of the
heating circuit.
On
Description
No circuit connected
Direct heating circuit, without mixing valve
Heating circuit for direct underfloor heating (CIRCA)
Swimming pool heating
Heating a circuit in summer, for example for a towel rail
Heating circuit with convection fans
Heating a domestic hot water tank
Controlling the electric heating element on a water heater
Controlling an electrical circuit based on the timer programme
Heating a circuit without a timer programme
The heating curve is set when the installation is commissioned,
thermostatic valves open if necessary. In event of major losses from the
building, it is necessary to adjust the gradient of the curve mid-season
then mid-winter in increments of 0.1 every 24 hours (building inertia).
To set the heating curve for a zone:
On
Parameter
Slope:
Max:
Base:
50 °C; 0 °C
MW-5000765-3
4. With the Custom notification notification type, set the number of
operating hours before a maintenance message is sent:
1. Follow the access path described below.
2. Select the value that corresponds to the type of circuit selected:
1. Select the icon for the zone to be modified;
2. Select Heating Curve.
3. Set the following parameters:
Description
Value for the heating curve gradient:
underfloor heating circuit: gradient between 0.4 and 0.7
radiator circuit: gradient of approx. 1.5
Maximum temperature of the circuit
Curve base point temperature (default value: Off = auto­
matic mode).
If Base: Off, the curve base point temperature becomes
equal to the room set point temperature
Water temperature in the circuit for an outdoor tempera­
ture. This data is visible all along the curve.
CIRCA
EHC-14
x
x
x
not available
x
x
not available
not available
not available
not available
, for example.