Installation; Installation Regulations; Positioning The Indoor Unit; Choosing The Location Of The Indoor Unit - Baxi MK SYSTEM Installation, User And Service Manual

Table of Contents

Advertisement

Icon
Information
DHW tank
Outdoor temperature
6

Installation

6.1

Installation regulations

6.2

Positioning the indoor unit

6.2.1

Choosing the location of the indoor unit

Fig.17
4 4
0
4 0
6.2.2

Affixing the indoor unit

Fig.18
1
4
2
7856310 - v02 - 21122023
0
3 0
0
3 0
0
1 5
0
MW-6070411-2
3
1
MW-6070415-02
Description of the icon
Temperature display for the domestic hot water
Outdoor temperature display
Caution
The appliance must be installed by a qualified professional in
accordance with applicable local and national regulations.
The location of the indoor unit must guarantee safety, be accessible for
maintenance, allow the front panel to be removed and the cover on the
user interface to be flipped up.
1. Take account of the dimensions shown opposite when choosing the
location of the indoor unit.
2. Choose a location that complies with the following specifications:
not exposed to water or dust,
close to a wall socket with protective earthing.
Once the location has been chosen for the unit, affix the indoor unit using
the side tabs.
1. Mark the positions of the 4 holes.
2. Drill the Ø 6 mm holes.
3. Insert the Ø 6 mm wall plugs.
4. Secure the indoor unit using Ø 3.5 mm screws.