Sign In
Upload
Manuals
Brands
Baxi Manuals
Heat Pump
MIC V200
Baxi MIC V200 Manuals
Manuals and User Guides for Baxi MIC V200. We have
1
Baxi MIC V200 manual available for free PDF download: Installation, User And Service Manual
Baxi MIC V200 Installation, User And Service Manual (140 pages)
Reversible air/water "Split Inverter" heat pump
Brand:
Baxi
| Category:
Heat Pump
| Size: 27.37 MB
Table of Contents
Table of Contents
2
1 Safety Instructions and Recommendations
6
Safety
6
General Instructions
7
Electrical Safety
7
Refrigerant Safety
8
Domestic Water Safety
8
Hydraulic Safety
9
Recommendations for the Installation
9
Recommendations for Operation
9
Specific Instructions for Service, Maintenance and Breakdowns
10
Liabilities
10
2 Symbols Used
11
Symbols Used in the Manual
11
Symbols Used on the Data Plate
11
Symbols Used on the Appliance
11
3 Technical Specifications
13
Homologations
13
Directives
13
Factory Test
13
Technical Data
13
Heat Pump
13
Heat Pump Weight
14
Domestic Hot Water Tank
15
Combination Heaters with Medium-Temperature Heat Pump
15
Sensor Specifications
17
Circulating Pump
18
Dimensions and Connections
19
Connection Plate
19
Indoor Module
20
Awhp 4.5 Mr
21
Awhp 6 Mr-3
21
Awhp 8 Mr-2
22
Electrical Diagram
23
4 Description of the Product
25
Main Components
25
Control Panel Description
27
Description of the Keys
27
Description of the Display
27
Schematic Diagram
30
5 Installation
33
Installation Regulations
33
Standard Delivery
33
Data Plate
33
Data Plate on the Indoor Module
34
Data Plate on the Outdoor Unit
34
Respecting the Distance between the Indoor Module and the Outdoor Unit
34
Positioning the Indoor Module
34
Choosing the Location for the Heat Pump
34
Allowing Sufficient Space for the Indoor Module
35
Install the Indoor Module in a Cupboard
35
Removing the Appliance's Front Panel
35
Positioning the Indoor Module
36
Levelling the Indoor Module
36
Attaching the Indoor Module to the Wall
36
Hydraulic Connections
37
Special Precautions for the Connection of the Heating Circuit
37
Special Precautions for the Connection of the Domestic Hot Water Circuit
37
Connecting the Various Circuits
38
Fitting the Condensate Collector Box
38
Setting the Thermostatic Mixing Valve
39
Checking the Heating Circuit
39
Filling the Installation
40
Cleaning and Flushing the Installation
40
Filling the Heating Circuit(S)
40
Fill the Domestic Hot Water Circuit
41
Putting the Outdoor Unit in Place
41
Allowing Sufficient Space for the Outdoor Unit
41
Selecting the Location of the Outdoor Unit
42
Choosing the Location of a Noise Abatement Screen
43
Selecting the Location of the Outdoor Unit in Cold and Snowy Regions
43
Installing the Outdoor Unit on the Ground
44
Refrigeration Connections
44
Preparing the Refrigerant Connections
44
Connect the Refrigerant Connections to the Indoor Module
45
Connecting the Refrigerant Connections to the Outdoor Unit
46
Testing the Leak-Tightness of the Refrigerant Connections
47
Evacuation
47
Opening the Stop Valves
47
Adding the Necessary Quantity of Refrigerant Fluid
48
Checking the Refrigeration Circuit
48
Electrical Connections
49
Recommendations
49
Recommended Cable Cross Section
49
Accessing the Pcbs
50
Routing the Cables
51
Description of the Connection Terminal Blocks
51
Connecting the Cables to the Pcbs
53
Connecting the Indoor Module
53
Electrically Connecting the Outdoor Unit
53
Connecting the Outdoor Unit Bus
55
5.10.10 Connecting the Outdoor Temperature Sensor
55
5.10.11 Connecting the Power Supply for the Electrical Back-Up
57
5.10.12 Checking the Electrical Connections
57
6 Commissioning
59
General
59
Commissioning Procedure with Smartphone
59
Commissioning Procedure Without Smartphone
60
CN1 and CN2 Parameters
60
Using the Installation Wizard on the Control Panel
61
Checking the Minimum Flow of the Direct Circuit
61
Setting the Flow Rate of the Second Circuit
62
Final Instructions for Commissioning
63
7 Settings
64
Modifying the Installer Parameters
64
Installer Menu
64
Installer \CIRCA and CIRCB Menu
64
Installer \CIRCA and CIRCB\ADV Menu
67
DHW Menu
67
Installer \DHW\ADV Menu
68
Installer \EHC-06 and SCB-04 Menu
68
Installer \EHC-06 and SCB-04\ADV Menu
70
Setting the Parameters
72
Language Selection
72
Selecting the Type of Outdoor Unit and the Type of Back-Up (CN1 Et CN2)
73
Setting the Heating Curve
74
Configuring the Estimated Electrical Energy Consumption Function
74
Configuring a Convection Fan or Underfloor Cooling
75
Screed Drying with the Aid of the Heat Pump
76
Drying Screed Without the Heat Pump Outdoor Unit
77
Configuring an On/Off or Modulating Thermostat
77
Configuring a Thermostat with a Heating/Cooling Control Contact
77
Setting the Parameters for Using Photovoltaic Energy
78
Connecting the Installation to a Smart Grid
78
Reducing the Noise Level of the Outdoor Unit
79
Detecting an Additional or Replacement PCB
80
COUNTERS /TIME PROG / CLOCK Menus
80
COUNTERS, TIME PROG, CLOCK \CNT Menus
80
Counters, Time Prog, Clock
81
COUNTERS, TIME PROG, CLOCK \CLK Menus
82
Description of the Parameters
82
Running the Back-Up in Heating Mode
82
Operation of the Switch between Heating and Production of Domestic Hot Water
83
Running the Back-Up in Domestic Hot Water Mode
84
Reading out Measured Values
85
Control System Sequence
86
8 Connection and Installation Examples
92
Installation with One Direct Underfloor Heating Circuit
92
Installation with 2 Heating Circuits: One Direct Radiator Circuit and One Underfloor Heating Circuit
93
Installation with a Direct Underfloor Heating Circuit and a Solar Circuit
95
Installation with a Swimming Pool
96
Connecting a Swimming Pool
96
Configuring Swimming Pool Heating
97
9 Operation
98
Browsing in the Menus
98
Description of the Pcbs
99
Start-Up
99
Shutdown
99
Switching off the Heating
99
Stopping Domestic Hot Water Production
100
Shutting down the Cooling Function
101
Frost Protection
101
10 Maintenance
102
Precautions to be Taken before Maintenance Operations
102
List of Inspection and Maintenance Operations
102
Drain the Appliance on the Heating Circuit Side
103
Draining the Domestic Hot Water Circuit
103
Clean the Magnetic Sieve Filters
104
Magnetic Filter Annual Maintenance
104
Full Cleaning of the Magnetic Filter
105
Cleaning the Plate Heat Exchanger
107
Checking the Magnesium Anode
107
Check the Hydraulic Pressure
108
Checking Operation of the Appliance
108
10.10 Replacing the Battery in the Control Panel
109
11 Troubleshooting
111
Resetting the Safety Thermostat
111
Error Messages
111
Error Codes
111
Fault Codes
114
Alarm Codes
115
Accessing the Error Memory
115
12 Decommissioning and Disposal
117
Decommissioning Procedure
117
Disposal and Recycling
117
13 Spare Parts
118
Indoor Module
118
Connection Plate
118
Casing
119
Control Panel
121
Hydraulic Circuit
123
Electrical Harnesses
125
Outside Unit
126
Awhp 4.5 Mr
126
Awhp 6 Mr-3
128
Awhp 8 Mr-2
131
14 Appendix
134
Product Fiche
134
Product Fiche - Temperature Controls
134
Package Fiche - Combination Heaters (Boilers or Heat Pumps)
135
Package Fiche - Medium-Temperature Heat Pumps
136
Advertisement
Advertisement
Related Products
Baxi Assure Mono 5
Baxi Assure Mono 7
Baxi Assure Mono 9
Baxi Assure Mono 12
Baxi Assure Mono 16
Baxi HELIS MI 1200
Baxi HELIS MI 900
Baxi Main 30 HE A
Baxi Luna Duo-Tec MP 1.60
Baxi Megao System 15
Baxi Categories
Boiler
Indoor Fireplace
Heat Pump
Water Heater
Thermostat
More Baxi Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL