8 Settings
Fig.44
Example of screed drying
programming in 3 stages.
°C
47
44
41
38
35
32
29
26
23
20
00:00
10 9 8
7
6 5 4
3 2 1
1
Access path
Parameter
Screed drying time
1
CIRCA >
ZP000
Set Screed
Drying > Stage 1
Screed start temp 1
ZP010
Screed end temp 1
ZP020
Access path
Parameter
Screed drying time
2
CIRCA >
ZP030
Set Screed
Drying > Stage 2
Screed start temp 2
ZP040
Screed end temp 2
ZP050
Access path
Parameter
Screed drying time
3
CIRCA >
ZP060
Set Screed
Drying > Stage 3
Screed start temp 3
ZP070
Screed start temp 3
ZP070
Access path
Parameter
Screed drying
enable
CIRCA >
ZP090
Set Screed
Drying
Signals/Counters
Screed temp setpoint
ZM000
Screed start time
ZM010
32
4
3
2
1
4
3
2
1
2
3
Description
Set the number of days spent in the first
screed drying step
Set the start temperature for the first step
of screed drying
The end temperature for the first step of
screed drying
Description
Set the number of days spent in the
second screed drying step
Set the start temperature for the second
step of screed drying
The end temperature for the second step
of screed drying
Description
Set the number of days spent in the third
screed drying step
Set the start temperature for the third
step of screed drying
Set the start temperature for the third
step of screed drying
Description
Enable the screed drying of the zone
To find out the setpoint temperature, start and end date and time for the
Screed drying function and the remaining drying time, at any moment,
refer to the following signals and counters:
Description
The current flow temperature setpoint for screed drying
The start date and time of the screed drying procedure
Stage 1
1
Stage 2
2
Stage 3
3
1. Configure the screed drying parameters for stage 1:
2. Configure the screed drying parameters for stage 2:
3. Configure the screed drying parameters for stage 3:
4. Activate screed drying:
The screed drying programme will start immediately and continue
for the number of days selected for each stage.
The system evaluates the setpoint temperature every 24 hours and
redefines it based on the remaining time for the stage.
Adjustment required
Number of days of drying for stage 1
Drying start temperature for stage 1
Drying end temperature for stage 1
Adjustment required
Number of days of drying for stage 2
Drying start temperature for stage 2
Drying end temperature for stage 2
Adjustment required
Number of days of drying for stage 3
Drying start temperature for stage 3
Drying end temperature for stage 3
Adjustment required
On