6.3.6

Installing and connecting the outdoor temperature sensor

Fig.25
3
2
4
MW-8800N003-6
Fig.26
Fig.27
2
1
Z
1/2 Z
1 Optimum location
2 Possible position
7856310 - v02 - 21122023
The connection of an outdoor temperature sensor is mandatory to ensure
the correct operation of the appliance.
1. Choose a recommended location for the outdoor temperature sensor.
2. Fit the two wall plugs (diameter 6 mm) delivered with the outdoor
3. Secure the sensor using the screws provided (diameter 4 mm).
4. Connect the cable to the outdoor temperature sensor.
Avoid placing the outdoor temperature sensor in a position with the
following characteristics:
Place the outdoor temperature sensor in a position that covers the
following characteristics:
2
1
H
1/2 H (min. 2,5 m)
temperature sensor.
Positions to be avoided
Masked by a building element (balcony, roof, etc.).
Close to a disruptive heat source (direct sunlight, chimney, ventilation
grille, etc.).
Recommended positions
On a façade of the area to be heated, on the north if possible.
Halfway up the wall of the area to be heated
Affected by changes in the weather
Protected from direct sunlight.
Easy to access.
1/2 H (min. 2,5 m)
H
H Inhabited height controlled by the sensor
Z Inhabited area controlled by the sensor
Connecting the outdoor temperature sensor
6 Installation
MW-3000014-2
1
2
MW-8800N001-3