8 Settings
Tab.14
Access path
Heat Pump >
23.5
Parameters, counters,
signals > Advanced
CIRCA > Parameters,
24.5
counters, signals > Settings
Tab.15
Configuration A - by default
Value of the pa
Value of the BL1
rameter
contact config pa
OTH LogicLev
rameter
contact
AP098
CP640
Closed (default val
Closed (default val
ue)
ue)
Closed (default val
Closed (default val
ue)
ue)
Tab.16
Configuration B
Value of the pa
Value of the BL1
rameter
contact config pa
OTH LogicLev
rameter
contact
AP098
CP640
Closed
Open
Closed
Open
Tab.17
Configuration C
Value of the pa
Value of the BL1
rameter
contact config pa
OTH LogicLev
rameter
contact
AP098
CP640
Open
Closed
Open
Closed
34
2. Configure the heat pump parameters.
On
Parameter
Description
BL input setting
Adjustment of the blocking input (BL1)
AP001
BL1 contact config
BL1 input contact configuration
AP098
Closed: cooling active when BL contact is
closed
Open: cooling active when BL contact is open
OTH LogicLev
Circuit contact logic level
contact
Closed: heating demand when contact is closed
CP640
Open: heating demand when contact is open
RevContactOTH cool
Reverse the contact in cooling mode for the cir
CP690
cuit demand
No: follows the heating logic
Yes: follows the reverse of the heating logic
3. Select one of the following configurations
The multifunction
input BL1 is:
Open
Closed
The multifunction
input BL1 is:
Open
Closed
The multifunction
input BL1 is:
Open
Closed
Operating mode for
If the OT contact is
the heat pump
open
Cooling
No cooling demand Cooling demand
Heating
No heating demand Heating demand
Operating mode for
If the OT contact is
the heat pump
open
Heating
No heating demand Heating demand
Cooling
No cooling demand Cooling demand
Operating mode for
If the OT contact is
the heat pump
open
Cooling
Cooling demand
Heating
Heating demand
Adjustment required
Heating Cooling
Closed
or
Open
Closed
or
Open
Yes
or
No
If the OT contact is
closed
If the OT contact is
closed
If the OT contact is
closed
No cooling demand
No heating demand