8.2

Searching for a parameter or a measured value

Tab.6
Access path
> Installation Setup > Search datapoints
8.3

Menu tree

On
8.4

Configuring the maintenance message

Type of notification:
None
Custom notification
7856310 - v02 - 21122023
To access the installer level:
1. Select the
2. Enter the code 0012.
The Installer level is activated
settings, exit the Installer level.
3. To exit the Installer level, select the
If no action is taken for 30 minutes, the system will automatically exit the
Installer level.
If you know the code for a parameter or a measured value, using the
Search datapoints function is the easiest way to access it directly.
1. Follow the access path described below.
On
2. Enter the code for the required parameter or measured value using
the knob.
3. Press the confirm button
The requested parameter or measured value is displayed.
Tab.7
Menus accessible using the
Disable installer access
Installation Setup
Commissioning Menu
Advanced Service Menu
Error History
System Settings
Version Information
The heat pump user interface is used to display a message whenever
maintenance is necessary.
To configure the maintenance message:
1. Select the
On
2. Select AP010 Service notification.
3. Select the desired type of notification:
Description
No maintenance message
The maintenance message will be displayed once the heat pump operating hours de­
fined by the parameters in the following table have elapsed.
icon.
Off
. After modifying the desired
On
On
to start the search.
button
Service Status icon.
8 Settings