9 Parameters
Parameters
Description of the parameters
HP silent mode
Heat pump silent mode level
HP058
No silent mode : normal operation
Silent mode level 1 : level 1 sound reduction
Silent mode level 2 : level 2 sound reduction, which is higher than level 1
Hybrid mode
Hybrid mode selection to choose on what basis the hybrid system will optimise
HP061
No Hybrid
Hybrid Cost
Primary Energy
Hybrid CO2
Peak elec cost
Peak rate electricity cost
HP062
Can be set from 0.01 to 655.35 cents per kWh
Off-peak elec cost
Off-peak rate electricity cost
HP063
Can be set from 0.01 to 655.35 cents per kWh
Gas or oil cost
Cost of gas per m3 or oil per litre
HP064
Can be set from 0.01 to 655.35 cents
Cool setpoint offset
Maximum offset applied to the cooling setpoint when a 0-10V humidity sensor is
HP079
used
Can be set from 0 °C to 15 °C
Humidity level
Relative humidity level over which the offset is added to the cooling setpoint
HP080
Can be set from 0 % to 100 %
Buffer tank
Activation of hydraulic management mode for the configuration with a low-loss
HP086
header, or for a buffer tank connected as a low-loss header
No
Yes
Buffer tank hyst
Temperature hysteresis to start or stop heating the buffer tank
HP087
Can be set from 0 °C to 30 °C
Offset heating - PV
Heating setpoint temperature offset when photovoltaic energy is available
HP091
Can be set from 0 °C to 30 °C
Offset DHW - PV
Domestic hot water setpoint temperature offset when photovoltaic energy is
HP092
available
Can be set from 0 °C to 30 °C
Low noise start time
Start time of the heat pump low noise function
HP094
Can be set from 0 Hours-Minutes to 143 HoursMinutes
Low noise end time
End time of the heat pump low noise function
HP095
Can be set from 0 Hours-Minutes to 143 HoursMinutes
CH Pump postrun
Central heating pump postrun time (in minutes)
time
PP015
Tab.30
> Signals
Signals
Pump running?
AM015
Pump speed
AM010
Dhw Temperature
BM000
Silent mode
AM002
Service required?
AM011
44
Description of the signals
Is the pump running?
Inactive
Active
The current pump speed in %
Dhw Temperature depending on loadtype this is TankTemperature or
DhwOutTemperature in °C
Silent mode function enabled
No silent mode
Silent mode level 1
Is service currently required?
No
Yes
Factory setting
EHC-14
No silent mode
No Hybrid
0.19 cents per kWh
0.15 cents per kWh
0.9 cents
5 °C
50%
No
3 °C
0 °C
0 °C
132 Hours-Minutes
36 Hours-Minutes
0 Min
7856310 - v02 - 21122023