8 Settings
Access path
Heat Pump> Parameters, counters,
23.5
signals > Settings > Advanced
Access path
Heat Pump > Parameters,
23.5
counters, signals > Settings >
Advanced
Access path
Heat Pump> Parameters,
23.5
counters, signals > Settings >
Advanced
8.17

Saving and restoring settings

8.17.1

Saving the installer details

8.17.2

Saving the commissioning settings

40
3. Turn on the electricity supply and switch on the heat pump.
4. Configure the heat pump input parameters.
The BL input setting (AP001) parameter corresponds to the BL1 input.
On
Parameter
BL input setting
AP001
BL2 function
AP100
The heat pump is ready to receive and manage Smart Grid signals.
5. Choose the contact directions of the BL1 IN and BL2 IN multifunction
inputs by setting the BL1 contact config(AP098) and BL2 contact
config. (AP099) parameters.
Parameter
BL1 contact config
AP098
BL2 contact config.
AP099
6. Configure the temperature offsets for the voluntary overheating by
configuring the Offset heating - PV HP091 and Offset DHW - PV
HP092 parameters.
Parameter
Offset heating - PV
HP091
Offset DHW - PV
HP092
The name and phone number of the installer can be saved so that the
user can find it easily.
1. Press the
2. Select System Settings > Installer Details.
3. Enter the name and phone number.
You can save all installation-specific settings. These settings can be
restored if necessary, for example after replacement of the main PCB.
1. Press the
2. Select Advanced Service Menu > Save Commissioning Settings.
On
3. Select Confirm changes to save the settings.
When you have saved the commissioning settings, the option Resetting to
commissioning settings is available in the Advanced Service Menu.
Adjustment required
Smart Grid ready
Smart Grid ready
Adjustment required
BL1 input contact configuration
Open = input active on Open contact
Closed = input active on Closed contact
BL2 input contact configuration
Open = input active on Open contact
Closed = input active on Closed contact
Adjustment required
Heating setpoint temperature offset when
photovoltaic energy is available
Domestic hot water setpoint temperature offset
when photovoltaic energy is available
button.
button.
7856310 - v02 - 21122023

Advertisement

Table of Contents