8 Settings
Parameter
Start day anti-leg
DP430
Start time anti-leg
DP440
8.12

Configuring a buffer tank

Tab.19
Access path
Parameter
Buffer tank
23.5
Air Src Heat pump >
HP086
Parameters, counters,
Buffer tank hyst
signals
HP087
> Settings
Boiler pump function
AP102
8.13

Improving domestic hot water or heating comfort

Tab.20
Improving hot water comfort
Access path
> DHW tank >
Parameters, counters,
signals > Settings
36
Description
Day to start the anti-legionella programme.
Only for weekly activation.
Time to start the anti-legionella programme.
On
Description
Installation with a low-loss header or a
buffer tank connected as a low-loss
header
Temperature hysteresis to start or
stop heating the buffer tank
Configuration of the boiler pump as
zone pump or system pump (feed
lowloss header)
OFF: No
ON: Yes
Parameter
Description
Max DHW duration
Maximum duration of the domestic
DP047
hot water production.
Min CH before DHW
Minimum heating duration between
DP048
two periods of domestic hot water
production.
Hysteresis DHW
Hysteresis temperature relative to
DP120
the DHW temperature setpoint
7. Choose the day and time to start the anti-legionella programme.
In installations equipped with a low loss header or a buffer tank connected
as a low loss header, it is necessary to activate the Buffer tank function.
1. Configure the buffer tank parameters.
The system does not allow the simultaneous production of heating and
domestic hot water. It is possible to alter the parameters to adapt the
operation of the product to your needs.
1. The timer programming for domestic hot water production can be
altered based on your night-time habits, for example.
2. If modification of the timer programming is not sufficient, go into the
domestic hot water setting parameters:
Adjustment required
Can be set from Monday to
Sunday
Can be set from 00:00 to
23:50 in increments of 10 mi­
nutes.
Adjustment required
Yes
Default value: 3 °C
Do not modify.
No
Adjustment required
Increase the maximum authorised
duration for domestic hot water pro­
duction.
Longer period of hot water produc­
tion.
Reduce the minimum heating dura­
tion between two domestic hot water
production runs.
The time between two periods of hot
water production is decreased.
Reduce the setpoint temperature dif­
ferential triggering the domestic hot
water tank load.
More frequent period of hot water
production.