4-3 Connecting I/O Terminal Block

WARNING

4-3-1 Factory default wiring

The following terminals are connected by short bars at the factory default. Remove these short bars when you connect
them to an external device.
Y1
X1
Y2
X2
Y3
X3
Y4
X4
Y5
X5
Y6
X6
Y7
X7
Y8
X8
Y9
X9
Y10
X10
Y11
X11
Y12
X12
Y13
X13
Y14
X14
X15
X16
X17
X18
X19
X20
I/O terminal block
• Do not short-circuit 24V OUT (X1, Y3) and 0V OUT (X3, Y1). Also, do not short-circuit IN COM. (X2) and OUT COM. (Y2,
X12, X15, X18). Starting the laser processing machine with these terminals short-circuited will cause the laser processing
machine to malfunction.
• To enable the laser radiation, connect the power supply to IN COM. and OUT COM. in addition to the above mentioned
terminals. Refer to "4-3-2 Connecting common terminals" (P.100).
• The following terminals of the I/O terminal block are the common terminals connected internally.
• X1 and Y3: 24V OUT
• X3 and Y1: 0V OUT
• Y2 X12, X15 and X18: OUT COM.
• Make sure that the power is turned OFF at wiring.
SHUTTER ENABLE IN
Short-circuited
OUT COM.
LASER STOP 1A IN
Short-circuited
OUT COM.
ME-VLW1-SM-8
LASER STOP 2A IN
Short-circuited
LASER STOP 2B IN
Short-circuited
OUT COM.
Short-circuited
LASER STOP 1B IN
99