4-3-2 Connecting common terminals

Connect IN COM.(X2) and OUT COM.(Y2) respectively to the power supply to supply power for input and output.
Common terminals (IN COM. or OUT COM.) on the I/O connector and the I/O terminal block are connected internally.
Supply the power to the one side of IN COM. and OUT COM.
NPN connection
PNP connection
• Do not invert the power wiring of I/O terminal and I/O connector. It may cause a failure.
• Do not short-circuit 24V OUT (X1, Y3) and 0V OUT (Y1, X3). Also, do not short-circuit IN COM. (X2) and OUT COM. (Y2,
X12, X15, X18). Starting the laser processing machine with these terminals short-circuited will cause the laser processing
machine to malfunction.
• Do not mix up with the external and internal power supplies.
• Do not mix the NPN and PNP connecting patterns.
• If you use the internal power supply of the I/O terminal block, make sure that the total load does not exceed 300mA.
• If you control the laser processing machine by the external power such as PLC, do not connect anything to the internal
power 24V OUT (X1, Y3) or 0V OUT (X3, Y1) of the I/O terminal block. If a short bar is installed, remove it.
• OUT COM. terminals of Y2, X12, X15 and X18 are the common terminal connected internally. Supply the power to one of
them.
„ To use the internal power (the I/O terminal block is not connected to an external control
device)
NPN connection
0V OUT
Y1
OUT COM.
Y2
Short-
Y3
circuited
Y4
Y5
Y6
I/O terminal block
„ To use the external power (connected to an external control device such as PLC)
NPN connection
IN COM.
24V
OUT COM.
0V
External power
supply
100
Use the internal power
IN COM. (X2)
-
24V OUT (X1)
OUT COM. (Y2)
-
0V OUT (Y1)
IN COM. (X2)
-
0V OUT (X3)
OUT COM. (Y2)
-
24V OUT (Y3)
24V OUT
X1
IN COM.
X2
Short-
X3
circuited
X4
X5
X6
Y1
X1
Y2
X2
Y3
X3
Y4
X4
Y5
X5
Y6
X6
I/O terminal block
Use the external power
IN COM. (X2)
OUT COM. (Y2)
IN COM. (X2)
OUT COM. (Y2)
PNP connection
OUT COM.
24V OUT
Short-
circuited
PNP connection
Y1
Y2
Y3
Y4
Y5
Y6
I/O terminal block
ME-VLW1-SM-8
-
24V
-
0V
-
0V
-
24V
Y1
X1
IN COM.
Y2
X2
0V OUT
Y3
X3
Short-
Y4
X4
circuited
Y5
X5
Y6
X6
I/O terminal block
OUT COM.
X1
IN COM.
X2
X3
External power
X4
supply
X5
X6
24V
0V

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Vl-w1500Vl-w1a00Vl-w1506Vl-w1a06

Table of Contents