5-3-2 Communication conditions

Item
Communication protocol
Standards
Applicable cable
Applicable HUB (or rooter)
IP address
Subnet mask
Default gateway
Port
Start code
Check sum
Delimiter
Reception timer
*1 : Do not use "127" in the first octet.
• The communication control of the laser processing machine through the Ethernet should be performed in a secure
network environment.
• Even the IP Address and Subnet Mask values are within the configurable range, they may not be available depending on
the combination.
• For the details of the setting method of communication conditions, refer to "3-5-2 Communication condition setting"
(P.80).
Ethernet communication conditions
TCP/IP
IEEE802.3ab (1000BASE-T) / IEEE802.3u (100BASE-TX) / IEEE802.3 (10BASE-T)
Category 5e or higher
• To connect an external device and one laser processing machine: Cross cable
• To connect an external device and two or more laser processing machines
through a HUB or a router: Straight cable
1000BASE-T / 100BASE-TX / 10BASE-T compatible
1.0.0.0 to 223.255.255.255 *1 / Initial value : 192.168.1.5
128.0.0.0 to 255.255.255.254 / Initial value : 255.255.255.0
1.0.0.0 to 223.255.255.255 *1 / Initial value : Unspecified (0.0.0.0)
5001 to 65534, except 9090 and 9091 / Initial value: 9094
• Setting request, Reading request, Reading response: STX
• Normal response: ACK
• Abnormal response: NAK
OFF
CR fixed
Timeout monitoring ON (10 sec.)
ME-VLW1-SM-8