Opening & safety sensor for automatic sliding doors (2 pages)
Summary of Contents for BEA EAGLE
Page 1
EAGLE Unidirectional activation sensor for Visit website for automatic, pedestrian doors available languages of this document. main connector wide zone antenna narrow zone antenna push buttons cover 75.5601.04 EAGLE 20240412 Page 1 of 8...
◊ If mounting horizontally, the sensor must be mounted in front of the door. ◊ If mounting vertically, the sensor must be mounted above the door. How to Open the Sensor: BEFORE MOUNTING AFTER MOUNTING Page 2 of 8 75.5601.04 EAGLE 20240412...
MOUNTING & WIRING If using EAGLE SPACER or EAGLE SPACER V, please refer to User’s Guide 75.5981 before beginning. Apply the mounting template. Drill 1 hole for the cable and pull it through. Drill 2 holes for the screws. Connect the wires accordingly:...
When mounting at the maximum height, the sensor manufacturer recommends a 15° tilt angle. Observe antenna type (narrow or wide) in the illustrations below. LATERAL ADJUSTMENT WIDE NARROW 10 ft 7 ft VERTICAL ADJUSTMENT WIDE NARROW 7 ft 10 ft Page 4 of 8 75.5601.04 EAGLE 20240412...
Once you have saved an access code, you always need to enter this code to unlock the sensor. If you forget the access code, cycle the power. For the first minute, you can access the sensor without an access code. PUSH BUTTONS ZONE SIZE FACTORY RESET > 2 sec 75.5601.04 EAGLE 20240412 Page 5 of 8...
Sensor does not respond Batteries in the remote Check batteries and change if necessary. to the remote control control are weak or installed improperly. Remote control not pointed Point remote control at sensor. correctly. Page 6 of 8 75.5601.04 EAGLE 20240412...
Page 7
NOTES 75.5601.04 EAGLE 20240412 Page 7 of 8...
Page 8
BEA, INC. INSTALLATION/SERVICE COMPLIANCE EXPECTATIONS BEA, Inc., the sensor manufacturer, cannot be held responsible for incorrect installations or incorrect adjustments of the sensor/device; therefore, BEA, Inc. does not guarantee any use of the sensor/device outside of its intended purpose. BEA, Inc. strongly recommends that installation and service technicians be AAADM-certified for pedestrian doors, IDA-certified for doors/gates, and factory-trained for the type of door/gate system.
Need help?
Do you have a question about the EAGLE and is the answer not in the manual?
Questions and answers