■Return value
Value
MMC_OK
MMERR_DEV_UNOPEN
MMERR_ARGUMENT_0
=1 to 9: Argument location
■Point
• When a bool label is specified to an interrupt factor label, setting interrupt condition judge value 1 is not required because
the API library automatically sets the mask value.
• When a bool label is specified to an interrupt factor label, specify one of the following to the interrupt condition.
• MMC_INT_CONDITION_CHANGE_BIT
• MMC_INT_CONDITION_ALL_BIT_ON
• MMC_INT_CONDITION_ALL_BIT_OFF
• MMC_INT_CONDITION_BIT_ON
• MMC_INT_CONDITION_BIT_OFF
• The interrupt factor No. (1 to 8) is used inside the API library therefore it cannot be used by the user program.
• The interrupt parameter is enabled by turning OFF→ON the user program READY signal [Y0].
• When a value outside the set range is set to the member variable of a structure, the No. of the member variable (1 or more)
is stored to the details error code.
• When MMC_NULL_LABEL is specified to label, the interrupt parameter of the interrupt No. specified by IntNumber is
initialized.
• The operation of the controller class SetInterruptParameter method is the same as the operation of this method.
■Supported version
API version
1.00
■Reference
None.
Description
Function succeeded
The Open method of the device driver class has not been called.
The argument is outside the set range.
Software version
01
3 API LIBRARY DETAILS (BASIC FUNCTIONS)