Safety Notices - Dentsply Sirona Midwest T1 Energo Instructions For Use Manual

Table of Contents

Advertisement

Available languages

Available languages

Dentsply Sirona
®
Instructions for use Midwest
T1/T2 Energo™
Obligations of the user
Preventing the spread of infections and
cross contamination
Emitted cooling air
Sufficient cooling
Instrument head overheating
Malfunction or damage
Spare parts and accessories
First aid measures in the case of
lubricant accidents
Operating conditions:
68 19 200 D3751
D3751.201.03.02.02    2023-11
2

Safety notices

Protect yourself, the patient, and any third parties from danger. Observe
the safety information, the intended use, the applicable hygiene standards,
occupational safety regulations, and accident prevention measures.
CAUTION!  Risk of contamination!
Prevent the spread of infection and cross contamination between
patients, users and third parties.
Before initial start-up and after every treatment, the product and
accessories must be reprocessed, see "Reprocessing" section.
Take the appropriate hygiene measures, e.g., wear protective gloves.
Filtered water
CAUTION!  Risk of burns! Use filtered water only (< 50 µm).
NOTICE!  The cooling air emitted by the coupling of the motor must
have a flow rate of 1.5 - 10 Nl/min.
CAUTION!  Risk of burns! Insufficient cooling leads to overheating of
the preparation site and to damage to the tooth substance. Ensure that
the water content is ≥ 50 mL/min.
CAUTION!  Risk of burns! If the instrument is defective, the area
around the instrument head may heat up.
CAUTION!  Risk of injury/Risk of burns! In case of malfunction, an
unusual or different operating sound, or damage, stop using the
instrument immediately and notify your dental depot or the manufacturer.
Repair
CAUTION!  Risk of burns!
Do not repair the instrument yourself.
Safe operation cannot be guaranteed if proper repairs have not been
carried out. Contact the dental depot / manufacturer.
CAUTION!  Risk of injury! Use only original Dentsply Sirona parts or
parts approved by Dentsply Sirona. Safe operation is not guaranteed for
parts that have not been approved by Dentsply Sirona.
The warranty does not cover defective products for which original spare
parts were not used.
General information:
After inhalation:
After skin contact:
After eye contact:
After swallowing:
Temperature: +10 °C – +30 °C.
If you have any questions, please contact your dental depot or the
manufacturer.
Immediately remove any clothing soiled
by the product.
Supply fresh air; consult doctor in case
of complaints.
If skin irritation continues, consult a doc-
tor.
Rinse opened eye for several minutes
under running water.
If symptoms persist, consult a doctor.
2 Safety notices
7