Orientalmotor alphaSTEP ARL Series Setting Manual page 49

Table of Contents

Advertisement

Monitor item
I/O
RIO
RX8 (RX13)
RX9 (RX14)
RX
DIO
In1
S-IN
ALL
(OUT1)
(OUT2)
(OUTA)
Enc
(RW)
(RWw1)
(RWw2)
(RWr1)
(RWr2)
(RWr3)
(RWr4)
(RWr5)
(RWr6)
(RWr7)
(RWr8)
Display
(TW-END)
Press the F4 to change the status of TW-END to
F4: ON/OFF
ON or OFF.
CRD
Press the F4 to change the status of CRD to ON
F4: ON/OFF
or OFF.
ALL
It is possible to switch each signal between ON and
OFF state by pressing the specified numerical key.
BASIC mode
from the left, (9) MOVE, (8) END, (7) T-UP, (6) /ALM,
(5) AREA, (4) T-RDY, (3) TW-END, (2) CRD and
(1) TIM.
ADVANCED mode
from the left, (←) MOVE, (→) END, (9) T-UP,
(8) /ALM, (7) AREA, (6) R-ERR, (5) S-BSY,
(4) M-BSY, (3) R-END, (2) W-END, (1) T-RDY,
(0) TW-END, (.) CRD and (+/-) TIM.
(STOP)
∗ is displayed if the input is active.
• is displayed if the input is non-active.
FREE
(START)
+LS
∗ is displayed if the input is active.
• is displayed if the input is non-active.
−LS
HOME
SLIT
IN
The status of all DIOs can be checked.
∗ is displayed if the input is active.
S-IN
• is displayed if the input is non-active.
The IN (inputs) are, from the left, (STOP), FREE and
(START).
The S-IN are, from the left, +LS, −LS, HOME and
SLIT.
(OUT1)
Press the F4 to change the status of OUT1 to ON
F4: ON/OFF
or OFF.
(MBC)
Press the F4 to change the status of MBC to ON
F4: ON/OFF
or OFF.
(OUT)
It is possible to switch each signal between ON and
OFF state by pressing the specified numerical key.
From the left, (9) OUT1 and (8) MBC.
ASG/BSG
Encoder pulse output is displayed.
∗ is displayed while pulse is being output.
(w0)
The values in the remote registers RWw0 to RWw3
(w1)
are displayed.
(w2)
(w3)
(w4)
The values in the remote registers RWw4 to RWw7
(w5)
are displayed.
(w6)
(w7)
(r0)
Use the numerical keys and F4 to change the
value in the RWr0.
(r1)
Use the numerical keys and F4 to change the
value in the RWr1.
(r2)
Use the numerical keys and F4 to change the
value in the RWr2.
(r3)
Use the numerical keys and F4 to change the
value in the RWr3.
(r4)
Use the numerical keys and F4 to change the
value in the RWr4.
(r5)
Use the numerical keys and F4 to change the
value in the RWr5.
(r6)
Use the numerical keys and F4 to change the
value in the RWr6.
(r7)
Use the numerical keys and F4 to change the
value in the RWr7.
8 Manual operation and I/O checking
Description
Display range
00~63
0:OFF
1:ON
0000h to FFFFh
0000h to FFFFh
0000h to FFFFh
0000h to FFFFh
0000h to FFFFh
0000h to FFFFh
0000h to FFFFh
0000h to FFFFh
0000h to FFFFh
0000h to FFFFh
−49−