Orientalmotor alphaSTEP ARL Series Setting Manual page 13

Table of Contents

Advertisement

7.
Press the
ENT .
The positioning-method setting screen is displayed.
Abs: absolute positioning
Inc: incremental positioning
8.
Press the
or
ENT .
The positioning method is confirmed and the position setting
screen is displayed.
9.
Enter the "−2400" using the numerical keys and press the
ENT .
The position is confirmed and the operating speed setting screen
is displayed.
10.
Enter the "1500" using the numerical keys and press the
ENT .
The operating speed is confirmed and operating fuction setting
screen is diplayed.
SingleMotion: Single-motion operation
LinkedMotion: Linked-motion operation
PushMotion: Push-motion operation
11.
Press either the ←
The operating function is confirmed. Data number is automatically incremented by one, and the setting
screen for No.03 is displayed.
12.
In order to stop creating operating data, press the
The first screen of the monitor mode is displayed.
It is possible to create up to 63 operating data from No.01 to No.63.
Press the
↑ ,
,
number using the numerical keys.
• Pressing the the ↑
and
• Pressing the
and
No.25
No.14
No.15
No.05
to select Inc and press the
or
to select the SingleMotion, and press the
← or
to select the data number. It is also possible to select a data
causes the number of tens to increase and decrease, respectively.
causes the number of units to increase and decrease, respectively.
No.16
ENT .
ESC
.