SECTION
9
TROUBLE
SHOOTING
IF UNIT
FAILS TO START,
check
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
Wiring
system
for wrong
lead
connections
Temperature
and/or
pressure
shutdown
reset
on
control
panel
and/or
reset
relay
in control
box
Fuses
in control
enclosure
or starter
enclosure.
Compressor
motor
starter
overload
heaters
and
adjusting
knob
Oil cooler
fan motor
overload
heaters
and adjusting
knob
Low oil pressure
or faulty
low oil pressure
switch
Contacts
of timing
relay
for low oil pressure
shut-
down
stuck
open
Faulty
timing
relay.
Reduced
voltage
starter
only — starting
phase
time
set too long
Reservoir
pressure
switch
setting
UNIT
STARTS
BUT
STOPS
AFTER
A SHORT
RUN,
check
1.
2.
3.
4.
5.
6.
7.
8.
9
High
(a)
(b)
(c)
(d
(e)
(f
(9)
(h)
(i)
(j
air discharge
temperature
caused
by
Low compressor
oil level
Clogged
oil cooler
or oil filters
Thermal
control
(thermostatic
mixing)
valve
in
operative
Dirt on oil cooler
core
faces
Poor ventilation
of unit and/or
oil cooler.
Water
control
valve
inoperative
Water
inlet
temperature
too high
Water
shutoff
valve
inoperative
On remote
oil cooler
unit
pilot-operated
valve
or check
valve in piPing to oil cooler
inoperative
Reservoir
pressure
switch
setting
Fuses
in control
panel enclosure
or starter
enclosure
Compressor
motor
starter
overloads
and
adjusting
knob
Oil cooler
fan motor
overload
heaters
and adjusting
knob
Low oil pressure
or faulty
low oil pressure
shutdown
switch.
Time delay
on timing
relay
for low oil pressure
shut-
down
set
too
short
a
time
MAXIMUM
DELAY
SETTING
IS 15 SECONDS.
Timing
relay
setting
screw
not engaged
(a)
Faulty
or intermittent
HDTS
or probe.
(b)
Incorrect
HDTS
setting
(225°
F. is maximum).
Faulty
timing
relay.
COMPRESSOR
DOES NOT UNLOAD,
check
1.
Magnetic
unloader
or
pressure
switch
for
mal
function
2.
3.
4.
5.
6.
7.
8.
Control
lines
for restriction
Air leaks
in control
system.
Inlet
valve
stuck
open
due to corrosion
Inlet
valve
disc
not sealing
Broken
inlet
valve
stem
spring
Pilot
or pressure
switch
adjustment
Pilot
or
pressure
switch
for
dirt
or
leaking
diaphragm
PNEUMATIC
BLOWDOWN
VALVE
CONTINUES
TO
PASS
AIR,
check
for
1.
Loose
or broken
air
line
to blowdown
valve
pilot
2.
Loose wiring to the blowdown
valve actuator
solenoid
3.
Coil failure
on the blowdown
valve actuator
solenoid
4.
Pressure
regulator
not set to correct
pressure.
EXCESSIVE
OIL CONSUMPTION,
check
for
1.
Oil carryover
through
discharge
line caused
by
(a)
Overfilling
the
reservoir.
(b)
Clogged
broken
or loose
oil return
lines
(c)
Ruptured
oil separator
elements
(d
Loose
assembly.
(e)
Incorrect
oil causing
foam
(f
Inoperative
minimum
pressure
valve
2.
Oil leaks
at all fittings
and gaskets
3.
Oil leaking
into water
system
of oil cooler.
COMPRESSOR
LOW
ON
DELlVERY
AND
PRES-
SURE,
check
for
1.
2.
3.
4.
5.
6.
7.
13-9-630
Section
9
Clogged
air filter.
Restricted
inlet
valve
Corrosion
in inlet
valve
causing
sticking
Broken
inlet
valve
stem
spring.
Binding
inlet
valve
piston.
Incorrect
motor
speed
Pressure
gauge
faulty.