Gardner Denver ELECTRA-SAVER II Service Manual page 46

Stationary base mounted compressor
Hide thumbs Also See for ELECTRA-SAVER II:

Advertisement

SECTION
8
MAINTENANCE
SCHEDULE
SERVICE
CHECK
LIST
Air Fiiter
Operating
conditions
determine
frequency
of service
refer
to'' Air Fiiters"
Section
6 and pian
maim
tenance
accordingly.
Oii Separator
Change
the oil separator
element
when
pressure
differential
gauge
indicates
an 8 PSI differential
Refer
to "Compressor
Oil
Separatot"
in Section
5
for
further
details
Motor
Lubrication
— See
Section
2.
Every
8
Hours
Operation
1.
Check
the reservoir
oil ievel — add oil if the oil level
is in the
ADD
range
with
the
compressor
on load
if oil consumption
is high, refer
to "Compressor
Oil
Separator"
in Section
5 and" Excessive
Oil Consump
tion"
in Section
9.
2.
Observe
if the
unit loads
and
unloads
properly.
3.
Drain the moisture
traps on turn vaive and inlet valve
pilots and on separate
air receiver
and moisture
sep
arator,
if used
4.
If moisture
is noted
in the
oii
level
gauge
drain
accumulated
moisture
and see
Section
5 " Moisture
in the
Oii System".
Every 125
Hours
Operation
1.
Check
for
dirt
accumulation
on
radiator-type
oii
cooier
core faces
and on the fan and fan motor.
Blow
off dirt if accumulation
is excessive.
Every 1000
Hours Operation
1.
Change
the
oii filter
element
every
1000
hours
or
sooner,
or when
the indicator
on filter
is in "Change
Filter"
area
with
unit running
and
warmed
up
Every
2000
Hours
Operation
1.
if using GD800
Lubricating
Coolant
change
the com
pressor
oil.
UNDER
ADVERSE
CONDITIONS
CHANGE
MORE
FREQUENTLY
(refer
to
oil
Change
interval
in Section
5). Flush
the system
if
required
2.
The
use
of
Gardner-Denver
GD8000
Lubricating
Coolant
or other
synthetic
iubricant
may extend
the
required
change
interval
See'' Synthetic
Lubricants"
in Section
5.
13-9-630
Section
8
Page
1

Advertisement

loading

This manual is also suitable for:

EcqqnEcqsnEcqqoEcqso