SECTION
2
INSTALLATION
GENERAL—
On receipt
of the unit
check
for any damage
that
may
have
been
incurred
during
transit
Report
any
damage
or missing
parts
as soon
as possible
CAUTION
DO NOT electric weld on the compressor or base bear-
ings can be damaged
by passage
of current
LIFTING
UNIT
Proper
lifting
and/or
transporting
methods
must
be used
to prevent
damage
~CAUTION
lift
compressor unit
by base only
Do not use other
places
such as enclosure
motor
compressor oil dis-
charge manifold
and piping
as lifting points.
~DANGER
The eyebolts or lugs provided on the motor are for lifting
the motor only and should not be used to lift any addi
tional weight
All eyebolts must be securely tightened
When lifting the motor the lifting angle must not ex-
ceed 15 degrees
Failure to observe this warning may
result in damage or personal
injury.
Physical
size
and
weight
of unit
may
allow
use
of tow
motors
Unit
may also
be moved
into location
by rolling
on bars
LOUVERED
WINDOW
EXHAUST
FAN
.m.
ILOUVERED
,L,,., rim,,
COMPRESSOR
UNIT
~
%
A75119
FIGURE
1-2. –
TYPICAL
COMPRESSOR
ROOM
LOCATION
— The
compressor
should
be installed
in a
clean,
well-lighted,
well-ventilated
area
with ample
space
all around
for maintenance.
Select
a location
that provides
a cool, clean,
dry source
of air.
In some
cases
it may be
necessary
to install
the air filter at some distance
from the
compressor
to obtain
a proper
air supply.
The compressor
unit requires
electric
motor cooling
air as
well as air to the compressor
inlet
Proper
ventilation
MUST
be provided
( Figure
2-2);
hot air must be exhausted
from
the compressor
operating
area
A typical
inlet-outlet
air
flow arrangement
is shown
in Figure
1-2.
If the air-cooled
oil cooler
module
is to be installed
at a
location
remote
from
the
compressor
unit
be sure
that
adequate
ventilation
is provided
Figure
2-2.
Hot air must
be exhausted
from
the
oil cooler
area
Open
Unit
Open
With
Compressor
Oil Cooler
Oil Cooler
Size
Unit
Module
Module
125
HP
4400
19300
23700
150
HP
5200
19300
24500
~
* 80" F. Inlet Air
FIGURE
2-2.
MINIMUM
AIR*
FLOW
FOR
COMPRESSION
AND
COOLING
(Cubic
Feet/Minute)
VENTILATION
— The
unit
whether
air or water
cooled
requires
sufficient
air flow,
Figure
2-2,
for electric
motor
cooling.
Air is drawn
into the back and front of motor and
is discharged
out the sides
Do not block
air flow to and
from
the
unit
FOUNDATION
The
Electra- Saver
II
compressor
re-
quires
no special
foundation
but should
be mounted
on a
smooth
solid
surface
of sufficient
strength
to support
the
weight
of the unit
Whenever
possible
install
the unit near
level
Temporary
installation
may be made
at a maximum
of 10°
angle
lengthwise
or 30"
sidewise.
Mounting
bolts
are
not normally
required
However,
in
stallation
conditions
such
as piping
rigidity,
angle
of tilt
or danger
of shifting
from
outside
vibrations
or moving
vehicles
may
require
the
use
of mounting
bolts
to the
foundation
OIL
RESERVOIR
dRAIN
(Figure
3-1)
The
oil
res
ervoir
drain
valve
is located
near
the
center
of the
oil
reservoir
just below
the separator
tower.
The drain
valve
is approximately
4-1/2
inches
from the floor
level
If this
height
is not sufficient
to conveniently
drain
the oil some
other
methods
of providing
oil drain
are
1.
Elevate
the
compressor
unit
on the
foundation
to
obtain
the
desired
drain
height
2.
Construct
an oil sump or trough
below
the floor level
and
pump
or bail the drained
oil
3.
Pump
oil from
the
reservoir
filler
opening
or res
ervoir
drain
to a container.
ACOUSTIC
ENCLOSURE
— The
Electra-Saver
1P
unit is
furnished
with an acoustic
enclosure
over the compressor
13-9-630
Section
2
Page
1

Advertisement