Download Print this page

Gardner Denver ELECTRA-SAVER II Service Manual page 16

Stationary base mounted compressor
Hide thumbs Also See for ELECTRA-SAVER II:

Advertisement

SECTION
3
.
STARTING
& OPERATING
PROCEDURES
A new unit as received
from the factory
has been
prepared
for shipping
only.
Do not attempt
to operate
the unit until
checked
and serviced
as follows
1.
Compressor
Oil
Check
the
oil level
in the
oil
reservoir.
Add oil only if the oil level gauge
reads
in
the red ADD
OIL
range.
Do not mix different
types
of oils
The unit is shipped
filled with
Gardner-Denver
GD800
Lubricating
Coolant
which
is suitable
for the
first 2000
hours
under
normal
operating
conditions
REPLACE
OIL
FILTER
ELEMENT
EVERY
1000
HOURS.
Initial
fill
or filling
after
a complete
draining
of the
system,
may show
the oil level
beyond
the
red EX-
CESS
oil range
After
start-uD
oil will fall into the
operating
range
as system
components
are filled
If
necessary,
add
oil to bring
level
into the center
of
the
RUN
range
when
unit is operating
on load
see
Figure
4-5
for quantity
of oil required
DANGER
ALWAYS
STOP
THE
PRESSURE
BEFORE
PLUG
TO ADD
OIL
UNIT AND
RELEASE
AIR
REMOVING
OIL FILLER
During
unloaded
operation
and after
shutdown
the
system
will partially
drain
back
into the oil reservoir
and oil level will read
higher
than when
operating
on
load.
DO
NOT
DRAIN
OIL
TO
CORRECT
on the
next loaded
cycle or start
oil will again fill the system
and the gauge
will indicate
the operating
level
2.
Air Filter—
Inspect
the air filter to be sure it is clean
and tightly
assembled
Refer
to Section
6 "Air Filter"
for complete
servicing
instructions
Be sure inlet line,
if used,
is tight
and clean
3.
piping
— Refer
to Section
2 "installation"
and make
sure
the
piping
meets
all requirements
4.
Moisture
Separator
Trap
— The trap is constructed
of cast iron with side inlet and outlet connections
and
inverted
bucket
design
A stainless
steel
internal
strainer
is used in trap
it should
be checked
period
ically for clogging
and replaced
if necessary.
Repair
parts
are available
for trap cap
retainer
gasket
and
strainer.
See
package
outlines
for mounting
dimen
sions
of moisture
separator
trap
The
moisture
trap
must
be
primed
by filling
with
clean
water
prior to initial
start-up
of unit
5.
Electrical
— Check
the unit and user-installed
wiring
with
the
wiring
diagrams
furnished
to be sure
it is
properly
wired
See
Section
4 "Controls
and instru
ments'
for general
wiring
diagrams
and Section
2 for
installation
instructions
6.
Rotation
— Check
the
motor
rotation
by momen
tarily starting
the motor.
Compressor
drive shaft rota-
13-9-630
Section
tion is counterclockwise
standing
at the motor
end
7.
Operating
Light Test–
Observe
the operating
lights
on the
ON-OFF
switch
when
jogging
the
motor
in
Step
6.
Be sure
all lamps
are
operative
8.
System
Pressure–
Set the turn-valve
pilot inlet pilot
and
operating
air
pressure
switch
to the
desired
unload
pressure
and differential
DO NOT
EXCEED
MAXIMUM
OPERATING
PRESSURE
ON
THE
COMPRESSOR
NAME
PLATE
EXCEPT
AS
spec
IFIED
UNDER
"CONTROL
ADJUSTMENTS'
SEC-
TION
4.
9.
Operating
Mode
— Refer
to Section
4 for detailed
information
on the control
system.
STARTING
THE
UNIT
— The
Constant
Speed
with
Low
Demand
Mode
Unit
requires
only
pressing
of the
OFF/
RESET
and
then
the ON
push
button
The Automatic
StarVTimed
Stop
with
Low Demand
Mode
Units require
selecting
the desired
mode
of operation
(see
sectiOn
4) and then
pressing
first the RESET
and then the
ON
push
button
OBSERVE
UNIT
COLD
OR
UNIT
HOT
STARTING
PRO
CEDURES
Unit
Cold
— Close
the air service
valve (furnished
by cus
tomer)
between
the
main
air system
and
the
unit check
valve
if the unit is a water-cooled
heat
exchanger
model
open any manual
water
inlet wide open.
Start the unit and
run for one minute.
Open
the air service
valve
Since
the
unit is equipped
with a minimum
(65
PSIG)
pressure
dis
charge
valve,
no special
procedure
to maintain
unit reser-
voir pressure
is required
CAUTION
On Automatic
Start- Timed stop Mode
it is important
to open the service valve after 'starting
and before the
set discharge pressure is reached to prevent
the almost
immediate
shutdown
of the unit followed
by a restart
which may cause motor overload
heaters to overheat
and blow.
Unit
Hot — No warmup
period
is required
Close
the air
service
valve (furnished
by customerj.
If the unit is a water-
cooled
heat exchanger
model
open any manual
water
inlet
valves wide open
Start the unit
Open the air service
valve.
DAILY
CHECK
Refer
to Section
8 "Maintenance
Schedule".
STOPPING
THE
UNIT
Close
the
air
service
valve
(furnished
by
customer,
allow
the
unit
to
build
up to
full
unloaded
pressure
and
press
the
OFF
push
button
Stopping
the
unit
at a pressure
below
full receiver
may
cause
oil carryover.
The
oil reservoir
will automatically
blow down as the motor stops
If the unit is a water-cooled
heat exchanger
type
close
any manual
water
inlet valves
Open
the air service
valve
3
Page
1

Advertisement

loading

This manual is also suitable for:

EcqqnEcqsnEcqqoEcqso